• Replace the damaged mains cable only
with the spare parts cable. Speak to your
local Authorised Service Centre.
WARNING!
All electrical connections must be made
by a qualified electrician.
CAUTION!
Do not drill or solder the wire ends. It is
forbidden.
CAUTION!
Do not connect the cable without cable
end sleeve.
N
L
One-phase connection - 230 V~
N
L
3.4 Assembly
If you install the hob under a hood, please
see the installation instructions of the hood
for the minimum distance between the
appliances.
230V~
Green - yellow
Blue and blue
Black and brown
Two-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Apply a new wire end sleeve of 1.5 mm²
on each cable end. (special tool
required).
Cable cross section
400V 2~N
Two-phase connection - 400 V 2 ~ N
Green - yellow
Blue and blue
Black
Brown
min.
500mm
N
L1
L2
N
L1
L2
min.
50mm