Safety information
- Kinking or bending of the capillary leads to permanent failure of the device.
- Maintain a bending radius of ≥5 mm when routing the capillary.
Physical and toxicological features of the expansion medium that could escape in the event of a mea-
suring system break:
Control range
with
scale limit value
°C
≤200
≥200 to ≤350
≥350 to ≤500
a
At present, no limiting statement concerning health hazards in the event of short-term exposure and
low concentration in the event of a measuring system break has been made by a health authority. Fill-
ing fluid may leak in the event of a measuring system break (max. 3 cm
Hazardous
Ignition
reaction
temperature
°C
375
No
490
- -
1 Safety information
Hazardous
Toxicological specifications
to water
Irritant
Class 1, slight-
ly hazardous
Yes
Yes
Hazardous to
Toxic
health
No
a
No
No
3
).
5