Troubleshooting
Malfunction
Incorrect flushes (too soon, too late,
unwanted)
Water is running continuously into
the urinal ceramic.
Flushing out of the urinal ceramic is
inadequate.
Flush volume is inadequate.
No flush actuation
16
Cause
Detection distance
not set correctly
IR window is dirty or
wet
IR window scratched
Software fault
Technical fault
Flush time set incor-
rectly
Basket filter in
solenoid valve
clogged
Network failure
Action
▶ Optimise the detection
distance. → See
"Optimising the detection
distance", page 18.
▶ Clean or dry the IR window.
▶ Contact a skilled person.
▶ Restart the urinal flush
control. → See "Restarting
the urinal flush control",
page 18.
▶ Contact a skilled person.
▶ Set flush time. → See
"Setting the flush time",
page 18.
▶ Clean the basket filter. →
See "Cleaning or replacing
the basket filter", page 18.
▶ Check the power supply.