EXPLANATION OF THE CODES DISPLAYED ON THE SCREEN
EN
PROBLEM
E0
E0
E1
E1
E2
E2
E3
E3
E4
E4
E5
E5
TECHNICAL DATA
Connection voltage
Rated current
Length
Insulation
Materials
Weight
GENERAL PRODUCT PARAMETERS
Parameter
Overall
dimensions
(millimetre)
EEI(%)
Airborne acoustical noise
emissions (dB(A) re 1 pW)
Annual energy
consumption (kWh/a)
58
POSSIBLE CAUSE
Sensor circuit is broken or
shorted.
Voltage input is low.
Ventilating fan problem.
Compressor started self-
protection.
Compressor protects itself
against unusual running speed.
Control panel's overheating
warning
DC connection cable
AC power cord
C5H10
Polypropylene (case), high quality of polyurethane full
foam, CFC-free (insulation)
16 kg
Value
Height
485
Width
726
Depth
420
99
47
128
SUGGESTED REMEDY
Replace or connect the sensor.
Check the battery voltage or adjust
the battery monitor level ("H1", "H2",
"H3").
Check if the ventilation fan is blocked
or shorted.
Disconnect the device from the
power supply for 30 minutes, and
then restart the device.
Change the operating mode via the
control panel on the device.
Move the device to a place with
a well-ventilated installation
environment.
DC
12/24 V
AC
220-240 V~, 50 Hz
DC 12/24 V
4.2A/2.1A
AC
0.8 A
(approx.) 3.5 meters
(approx.) 2 meters
Parameter
Total volume (dm
Energy efficiency class
Airborne acoustical noise
emission class
Climate class:
(negative earth)
Value
3
or l)
52
E
D
SN/N/ST/T