15. Technical specifications
Test voltage
Test voltage resolution
Test voltage accuracy
Polarity
Leakage current
Leakage current resolution
Leakage current accuracy
Display
Ripple
Safety features
PC Interface
Advanced features
Built-in chronometer
Software MegaLogg2
Environmental protection
index
Safety
:
Up to 80,000 V.
:
100 V between 10 kV and 80 kV.
10V up to 9.99 kV.
:
± (2% of nominal value ± 2 digits) with 1 mA
load.
:
Negative voltage, ground positive.
:
Max. 10 mA.
:
0.01 mA.
:
± (2% of nominal value ± 2 digits).
:
Alphanumeric.
:
< 2%.
:
Remote control via Bluetooth.
Emergency stop buttons.
Self-detection of sparks.
Visual indicators (LEDs).
Sound indicator.
:
USB.
:
Ramp and SVT test.
"Pass-fail" and fixed time tests
Internal memory.
:
Indicates elapsed time from the beginning of
the measurement mm:ss format, up to 20:00.
:
It allows to transfer the data stored in the
equipment memory to a PC, to analyze
them, to present the results in tables and
graphs, to generate reports of the tests.
:
IP54 (with the cover closed).
:
Conforms to IEC 61010-1.