3.2 Delivery
Description
Paratherm unit with surveying / blocking-out arm
Thermal blocking-out instruments 0°, 2°
Undercut gauges 0.25 / 0.35 / 0.50 / 0.75 mm
Analyzing rod
Graphite holder
Replacement graphite markers
Plastic cover
Fuse T 0.25 A
Instructions for use with EEC-Declaration of conformity
4. Areas of use
Cast partial denture, combination techniques, conical crowns, positioning of snap attachments and
attachments.
5. Installation
Set the necessary voltage on the underside of the unit (110 / 220 / 240 V). Then connect the unit
to the mains supply. Stand the Paratherm on a level working area.
6. Operating the Paratherm
Mount the master model on the model table
already available or supplied with the unit.
Loosen the knurled screw  and raise the
sliding rods to the necessary level. Fasten
with retainer ring . Grip the instrument
eg. analyzing rod in the surveying handpiece
 and
push the selected blocking-out
instrument into the thermal blocking-out
handpiece .
Place the model table  in the most
convenient position on the work surface .
Loosen the locking screws , so that the
arms may be moved freely. Switch on the
thermal blocking-out handpiece  and set
the desired temperature (maximum 160 °C /
320 °F) on the controller .
Caution: Only change the
blocking-out instruments 
whilst they are still warm.
8
piece
1
1
0,25 mm
4
1
1
10
1
1
10
6.1 Electric wax knife
The knife is connected by means of the socket on the rear side of the unit. Only operate the wax-
knife with an instrument in the place.
Set the desired temperature on the potentiometer . Maximum temperature 280 °C / 536 °F.
Caution! Only change the knife whilst it is still warm.
6.2 Locking the surveying arm (Positioning attachments)
Rotate the surveying handpiece  forwards of the centre of the work surface and lock into the
position with screws  .
Grip the wire aid in the surveying arm and fix the level using . With the model already clamped
into position, guide the model table onto the wire aid. Correct the level.
When ordering spare parts please quote the unit number (type plate or rear side of the unit).
7. Spare parts
Description
Thermal blocking-out instrument
0,25 mm
0,35 mm
Undercut gauge
0,50 mm
0,75 mm
Analyzing rod
Graphite holder
Replacement graphite markers
8. Recommended accessories
(Not included in original kit REF 094-270-00)
Description
Thermal blocking-out instrument
EN
piece
REF
094-275-00
1
094-277-00
094-283-00
094-284-00
1
094-285-00
094-286-00
1
094-287-00
1
094-288-00
10
094-289-00
piece
REF
094-276-00
094-278-00
1
094-279-00
094-280-00
094-281-00
9

Publicidad

loading

Este manual también es adecuado para:

094-270-00