3.2 Technical Data FXC Lifting Magnet
FX lifting magnets work with a double magnet system. The inner magnetic circuit is opened by the
activation of the magnet system via lever (are attracted) or closed (no external force effect).
The dimensions and weights and permissible
Lifting forces Smooth surface (Ra < 6.3 microns ), please refer to the following tables:
Model
Max. Lifting capacity
from (mm)
FX-C175
10
FX-C250
12
FX-C450
15
*Da= diameter outside, Di= diameter inside • Safety factor 3 / test procedures according to EN 13155
When transporting workpieces with different dimensions or properties, it must be ensured that a safety factor of
3 is achieved.
Rings must have a minimum ring support width of 10 mm, 3,5 kg load per cm² support surface must be assumed,
whereby the maximum load must never be exceeded.
The specified load capacity is reduced as a function of material thickness, surface quality, inherent stability of the
Load, material properties, temperature of the load.
3.3 The main components of the FX-C lifting magnets are:
Magnetic body
Load-/
Type plate
Should these designated important parts be damaged or missing, the magnet has to be inspected by an
expert before further use.
Max. Lifting capacity
Dimensions (mm)
(kg)
D
Da-Di*
175
120 114-40 130
250
160 152-65 145
450
250 240-100 155
max. Operating temperature 80°C
note load charts and safety information beginning on page 54
Lifting eye
Max. Lifting capacity per
cm
ring surface (kg)
2
H
Bs
185
3,5
210
3,5
275
3,5
Lever
Magnetic poles
Dia min
Weight
(mm)
(kg)
60
7,5
85
15
120
35
Gear knob with
safety groove
19

Publicidad