6. Storage and disposal
Lifting magnets have to be stored in a way they do not tilt, fall or can slide. Lifting magnets should be stored
protected from the weather and corrosive substances. For longer storage, it is advisable to lubricate the
device. At the end of the use of lifting magnets or at end of life, the device must be disposed of properly and
environmentally friendly! Take note of the relevant provisions of the relevant authorities.
7. Spare parts for FX lifting magnets
FX lifting magnets consist of various components. These of course are also available as spare parts. The
following spare parts are available for all FX Lifting magnet models.
1. Lever
4. Top-Plate
Lifting Eye
FX-150, FX-R100, FX-P170, FX-VV200, FX-V150 HOT
FX-300, FX-R225, FX-P330, FX-VV400, FX-V300 HOT, FX-C175
FX-600, FX-800, FX-R450, FX-P650, FX-VV800, FX-V600 HOT, FX-C250
FX-1000, FX-1500, FX-R750, FX-C450
FX-2000, FX-3000, FX-R1200, FX-R1800
2. Type plate Set
X
5. Lifting Eye
Screws DIN 912 12.9
galvanized
Observe the tightening torque
3. Front and Rear Panel
6. Ball Bearings
X New (mm) X min. (mm)
10,7
10,1
13,6
12,9
15,6
14,8
21,4
20,3
29,1
27,6