Connecting The Return Water Canister; Start-Up; Switching On/Off; Filling In Water - Ivoclar Vivadent Ivomat IP3 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4.4 Connecting the return water canister

– Fill return water canister (20) to a depth of 3–5 cm.
– Insert the canister hose into the canister and screw
cap on (19).
– Put the canister on the floor in a suitable place.
– Lift the safety lever (2) and engage. Push the bolt to
the right using the knob (3) and lift the lid (4) of the
vessel.
– Remove protective insert used during transportation.

5. Start-up

5.1 Switching on / off
Take the polymerization container (29) with lid (27) out
of the pressure chamber. Switch on main (9) (0 to I). The
pilot lamp (10) will light up when the apparatus is ready
for use.
The apparatus may be kept ready for use
throughout the day (mains switch on I), but the
pressure chamber lid (4) should remain either
unbolted or open after each use.

5.2 Filling in water

Fill the pressure chamber with water.
– Maximum filling height: up to the market groove in
the chamber
– Minimum filling height: objects to be polymerized
must be completely under water
9

Publicidad

Tabla de contenido
loading

Tabla de contenido