Design Information
PRODUCT DIMENSIONS AND CLEARANCES FOR 48" MODELS
A WARNING:
Installations without a hood
require 48" minimum to combustibles
above the rangetop. A custom hood
installation with exposed horizontal
combustible surfaces must have
an Auto-On feature. Refer to hood
installation instructions for specific
hood clearances.
The surface of the entire back wall
above the countertop and below
the hood must be covered with
a non-combustible material such
as metal, ceramic tile, brick, marble
or other stone.
~
_
a7-te"to
Universal Utility Locations
@
Front of
>
Locate gas
" 17" |
inlet on back
wall or on
floor 2" from
back wall.
48" Minimum
to Combustibles
12" Minimum to
Adjacent Wall
\
i
12" Minimum
:
Each Side
se.
13" Max.
46-1/4" =~
22-3/4" Min.
* The opening between a 4" high backsplash must be 48"
to allow the rangetop to slide back against the wall.
12" Minimum to
Combustibles or 0" to
non-combustible
ADDITIONAL CLEARANCES:
material above the
each side.
48" Min. to
Combustibles
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and the
bottom of the wall cabinet.
Clearance