remove the worn blades by pulling them off, and then replace them with new ones, inserting the protru-
ding tooth into the socket;
replace the squeegee on the its support.
Fuses: replacement (battery models) (Fig. L)
The fuse protecting the electrical circuit is located on the battery bridge.
To replace it:
make sure the dirty water tank is empty and empty if necessary;
remove the dirty water tank to access the batteries;
lift the fuse holder lid (fig. L) and remove the fuse;
fit a new fuse and close the fuse holder cover.
lower the dirty water tank.
Fuse table: for the complete fuse table, see the spare parts catalogue.
Fuses: replacement (cable models) (fig. M)
The fuses protecting the electrical components are on the electrical components box.
To replace:
make sure the dirty water tank is empty and empty if necessary;
remove the dirty water tank to access the electrical components compartment;
open the cover of the fuse holder on the electrical components box and remove the fuse;
fit a new fuse and close the fuse holder cover.
lower the dirty water tank.
Fuse table: for the complete fuse table, see the spare parts catalogue.
If a fuse continues to blow, the fault in the wiring, boards (if present) or motors must be identified and repaired.
Have the machine checked by qualified personnel.
Routine maintenance
Daily operations
After each day's work, proceed as follows:
disconnect the machine from the power supply;
empty the dirty water tank and clean if necessary;
clean the squeegee blades and check for wear. If necessary, replace.
check that the suction hole in the squeegee is not blocked, if necessary remove encrusted dirt;
Battery model: charge the batteries according to the procedure described;
Weekly operations
clean the dirty water tank float switch and make sure it is working correctly;
clean the suction hose;
clean the dirty water tank and detergent tank;
Battery model: check the level of battery electrolyte and top up with distilled water if necessary;
Six monthly operations
Have the electrical circuit checked by qualified personnel.
IMPORTANT
Never use a fuse with a higher amperage than specified.