Descargar Imprimir esta página

Comunello LIWIN L40 Slim Instrucciones De Uso Y De Instalacion página 49

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 106
To create a synced group, using the MOWIN APP, do the following:
1) Position all actuator trimmers to be synchronized in M (SLAVE actuator state)
2) Place only the trimmer of one of the actuators in "A" (MASTER actuator status)
3) Power the MASTER actuator (or all actuators)
4) Create a "new synchronization" by following the Step by Step APP
7.3
CHAIN STROKES ADJUSTMENT
It is possible to adjust the stroke of the chain millimetrically through theAPP or manually through the special trimmer on the
front of the actuator. Below is the table with the various chain lengths corresponding to the positions of the trimmer.
To adjust the stroke of a single actuator move the trimmer to one of the 1-2-3-4 positions depending on the desired stroke.
350
TRIMMER
* SLAVE actuator
POSITION M
status
TRIMMER
200mm STROKE 400mm STROKE 650mm STROKE 850mm STROKE
POSITION 1
TRIMMER
250mm STROKE 500mm STROKE 700mm STROKE 900mm STROKE
POSITION 2
TRIMMER
300mm STROKE 550mm STROKE 750mm STROKE 950mm STROKE
POSITION 3
TRIMMER
POSITION 4
350mm STROKE 600mm STROKE 800mm STROKE 1000mm STROKE
(Factory setting)
** MASTER
TRIMMER
actuator/Wi-Fi
POSITION A
status active
* the actuator does not move unless it has first been synchronised with a MASTER actuator;
** The WIFI of the actuator is active and it is therefore possible to interact through the Mowin app. On the OPEN command, the
actuator makes the maximum stroke.
7.4
REPLACING A FAULTY ACTUATOR FROM A GROUP OF SYNCHRONIZED ACTUATORS
If it is necessary to replace a device in a synchronized group, proceed as follows:
1) Disconnect the actuators from the window;
2) Reset the actuators using the reset procedure (see chapter "8.
3) Activate the actuators individually by setting the trimmers to the stroke position and locate the faulty one;
4) Replace the non-functioning actuator with a new one;
5) Perform the manual or APP synchronization procedure.
7.5
ADDING OR REMOVING AN ACTUATOR FROM A SYNCHRONIZED GROUP
To add or remove one or more actuators from an already synchronized group, it is necessary to reset the synchronized group
and perform a new synchronization procedure.
STROKES SELECTABLE BY SNAP TRIMMERS
600
800
* SLAVE actuator
* SLAVE actuator
status
status
** MASTER
** MASTER
actuator/Wi-Fi
actuator/Wi-Fi
status active
status active
1000
* SLAVE actuator
status
** MASTER
actuator/Wi-Fi
status active
RESET PROCEDURE");
49

Publicidad

loading

Este manual también es adecuado para:

Liwin l40 slim wifiMl4s s vn nw 35h al00 iMl4s s vn nw 60h al00 iMl4s s vn nw 80h al00 iMl4s s vn nw 10h al00 iMl4s s rw nw 35l al00 i ... Mostrar todo