8. RESET PROCEDURE
The reset procedure allows the actuators to be returned to factory conditions. It is necessary to perform a RESET in the following
cases:
1) Actuators are to be reset to factory settings.
2) Synchronization failed.
3) The number of synchronized actuators must be increased or decreased.
4) It is necessary to replace an actuator on a group of synchronized actuators.
To perform a reset, proceed as follows:
1) Disengage the actuator(s) from the window.
2) Power the actuator(s) to be reset.
3) With the actuator(s) powered, move the Trimmer following the M-C-M-C-M-C-M sequence within 5 sec ("C" stands for stroke
and corresponds to one of positions 1-2-3-4).
4) The trimmer flashes three times.
5) At the end of the operation, all the motors will be reset to factory conditions and the LEDs will remain lit.
N.B.: In the case of a group of synchronized actuators, if all are energised, simply reset the MASTER and the SLAVEs will also
be reset.
Once the reset operation is complete and the trimmer is set to 'M', the actuator will not accept any opening or closing
commands.
Once the reset operation is completed, the actuator will only accept a complete closing command.
9. DIAGNOSTICS
Using the COMUNELLO MOWIN APP, it is possible to perform the Diagnostics operation to verify the errors encountered.
abnormal obstacle
wi-fi communication error between actuators
actuator alignment error
stop for encoder
10. MOWIN APP
The MOWIN app can be downloaded for free from Android and IOS stores.
The MOWIN APP is intended only for professional sellers and installers in the sector. The MOWIN APP is not intended for use
by children and/or incompetent persons.
In order to interact with an actuator (only in WIFI versions) through the MOWINAPP, it is necessary to activate the actuator's
WIFI. To activate the WIFI of an actuator, turn the trimmer to position "A".
As illustrated by the APP, to connect to the actuator it is necessary to scan the QR code on the product and packaging labels.