PROGRAMMING AND STARTING UP
6
SELECTION OF THE MODES AND PANEL FUNCTIONS (SW2)
Using SW2, choose the required options (see "SW2 functions" on page 48).
7
POTENTIOMETER ADJUSTMENT
8
START UP
Final checks
Following installation and programming, start up the
actuator and check the devices installed:
1 Check the correct operation of the control devices
(button, wall key and remote control).
See "Operation modes" on page 41.
2 Check the correct operation of the safety devices
(photocells).
See "A- Detection by the additional safety device
(photocell)" on page 42.
3 Place an obstacle and make the gate collide with it
in order to check operation in the event of collision.
See "B- Direct detection (sensibility of the opera-
tor): VULCAN VUS model operator (DIP12 ON, TOP9
only)" on page 42.
4 If everything is correct, close the panel cover.
Should the system not work correctly, find the
reason and solve it (check the section "Failure
diagnosis" on page 53).
52
Installation manual
Garage lighting time (T.LG) (TOP9 only)
If the garage lighting circuit has been connected to the
control panel, regulate the time which the lights shall
remain on using T.LG.
Minimum value: 3 seconds; maximum value: 90
seconds.
Open gate waiting time (T.E.)
If automatic operation mode is programmed
(DIP4=ON), regulate T.E. to adjust the waiting time
with the gate open (before automatic closing
begins).
Minimum value: 3 seconds; maximum value: 60
seconds.
Torque regulation (P.M.)
Correct
torque
adjustment
importance to prevent injury and damage.
Increased torque produces a more violent
impact.
• Hydraulic motors: set P.M. at the maximum value.
• Electromechanical motors: set P.M at the minimum
value
possible,
compatible
operation of the gate.
User instruction
1 Instruct the user with regards to the use and
maintenance of the facility and provide him/her with
the use manual.
2 Point to the gate, showing that it opens
automatically, and indicating how to operate it
manually.
Where
appropriate,
operation is using the remote control.
is
of
vital
with
the
proper
indicate
that

Publicidad