MAINTENANCE AND DIAGNOSIS OF FAILURES
Problem
The panel does not work and no
indicator LED comes on
The motor does not work, DL14 lit
up, DL6 and/or DL9 off
The motor does not work, DL14 lit
up, DL6 and DL9 lit up, DL10 and
DL11 off when operating the
controls
The motor does not work, DL14 lit
up, DL6 and DL9 lit up, the relay is
enabled (DL4 or DL5 and DL17
light up) when pressing PULS1,
PULS2
The leaf does not reach the stopper
The electrolock is not released
3
SPARE PARTS
If the panel needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
4
SCRAP
The control panel, up until the end of its useful
life, must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner we will avoid possible accidents and
damage to adjacent facilities.
54
Installation manual
Cause
Main circuit breaker SW1 in "OFF"
Absence of panel power supply
Electronic cut-out F2 blown
Transformer or switchboard failed
D L 6 a n d / o r D L 9 o f f i n d i c a t e
photocell error
F3 blown (whenever the photocells
are fed by way of the AUX 24Vac
panel connector)
The signal from the controls does
not reach the panel
Motor cut-out F1 blown
Motor connections
Defective motor
Opening programming incorrect
Ends of travel wrongly adjusted
The back pulse has not been
programmed
Electrolock or connections with
failure
Use only original spare parts.
}
The control panel must be deposited in the
appropriate containers for subsequent recycling,
separating and classifying the different materials in
line with their nature. NEVER deposit it in domestic
rubbish or in landfills which are not controlled, as
this will cause environmental damage.
Solution
Place SW1 in "ON"
Re-establish the power supply
Replace F2 using another fuse of
the same value and investigate the
cause of failure of F2
Call the technical service
Remove the obstacle or check the
photocells
Replace F3 using another fuse of
the same value and investigate the
cause of failure of F3
C h e c k t h e c o n t r o l s a n d t h e
connections
Replace F1 using another fuse of
the same value and investigate the
cause of failure of F1
Check connections
Replace motor equipment
C a r r y o u t t h e p r o g r a m m i n g
correctly
Adjust ends of travel
Place DIP5 in ON
C h e c k t h e c o n n e c t i o n s a n d
electrolock