Installation; Transducer Installation - Balluff BTL5-P-3800-2 Serie Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL5-S1_ _B-M_ _ _ _-P-(SA244)-S32/S147/KA_ _
Micropulse Linear Transducer in Profile Housing
3

Installation

3.1

Transducer installation

Ensure that no strong electrical
or magnetic fields are present in
the immediate vicinity of the
transducer.
Any orientation is permitted.
The supplied mounting brackets
and cylinder head screws allow the
transducer to be mounted on a flat
machine surface.
BTL5...P-S32/S147
Fig. 3-1: Dimensional drawing (BTL5...P-... transducer with floating magnet BTL5-P-3800-2)
BTL5...P-KA...
Fig. 3-2: Dimensional drawing (BTL5...P-... transducer with captive magnet BTL5-F-2814-1S)
4
english
A sufficient quantity of mounting
brackets is supplied.
Recommended installation:
Distance A = approx. 80 mm
Distance B = approx. 250 mm (be-
tween the individual clamps)
To prevent resonant frequencies
under vibration loads of >50 g, we
recommend placing the mounting
clamps at irregular intervals.
NL
Nominal stroke
Mounting brackets with isolation bushings
and M5 × 22 cylinder head screws, DIN 912,
max. tightening torque 2 Nm
Nominal stroke
Mounting brackets with isolation bushings
and M5 × 22 cylinder head screws, DIN 912,
max. tightening torque 2 Nm
NL
Magnet
The supplied isolation bushings
are used to electrically insulate the
transducer from the machine
(➥ ➥ ➥ ➥ ➥ Fig. 3-1 respectively 3-2 and
section 5.6 Noise elimination).
The Micropulse transducer in pro-
file housing is suitable both for
floating, i.e. non-contacting mag-
nets (➥ ➥ ➥ ➥ ➥ page 5) and for captive
magnets (➥ ➥ ➥ ➥ ➥ page 5).
unusable area
Black,
round
marking

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl5-p-5500-2 serieBtl5-p-4500-1 serie

Tabla de contenido