Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage; Control Signals - Balluff BTL5-P-3800-2 Serie Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL5-S1_ _B-M_ _ _ _-P-(SA244)-S32/S147/KA_ _
Micropulse Linear Transducer in Profile Housing
8

Technical Data

The following are typical values at DC 24 V and room temperature. Fully operational after power-up, with full accu-
racy after warm-up. Values are with BTL5-P-3800-2, BTL5-P-4500-1 or BTL5-P-5500-2 magnet held at a constant
offset from the transducer or with captive magnet BTL5-F/M/N-2814-1S (see magnet section for exceptions):
Resolution (LSB)
depending on version:
BTL5-S1_2...
5 µm
BTL5-S1_3...
10 µm
BTL5-S1_4...
20 µm
BTL5-S1_5...
40 µm
BTL5-S1_6...
100 µm
BTL5-S1_7...
2 µm
BTL5-S1_8...
50 µm
Non-linearity
for resolution < 10 µm
for resolution > 10 µm
Output data
The maximum sampling fre-
quency f
at which each sample
A
provides a new actual value can
be determined from the following
table:
[mm]
Nom. length
< 100
Nom. length
< 1000
Nom. length
< 1400
Nom. length
< 2600
Nom. length
< 4000
Fig. 8-1: Diagram
Hysteresis
Repeatability
(resolution + hysteresis)
Temperature coefficient
(6 µm + 5 ppm * nominal length)/K
Lag error
Standard
2.5 frames
SA244
< 1 frame
Shock loading
100 g/6 ms
1
per IEC 60068-2-27
Continuous shock
100 g/2 ms
1
per IEC 60068-2-29
Vibration 12 g, 10 to 2000 Hz
1
per IEC 60068-2-6
1
Individual specifications as per
Balluff factory standard
8.1
Dimensions, weights,
ambient conditions
Nominal length
Dimensions
Weight
Housing
Housing attachment
Mounting clamps with isolation
bushings and screws
± 30 µm
Operating temp.
± 2 LSB
Humidity < 90%, non-condensing
Protection class per IEC 60529
IP 67 when closed up
8.2
Supply voltage (external)
Regulated supply voltage
BTL5-S1...
Ripple
[Hz]
Current draw
1500
Inrush
1000
Polarity reversal protection built-in
Overvoltage protection
666
Transzorb diodes
500
Electric strength
GND to housing 500 V
333
< 1 LSB
< 2 LSB
89/336/EEC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Electro-
magnetic Compatibility, has con-
firmed that Balluff products meet
the EMC requirements of the fol-
lowing Generic Standards:
EN 61000-6-4 (emission)
EN 61000-6-2 (noise immunity)
< 4000 mm
➥ ➥ ➥ ➥ ➥ page 4
approx. 1.4 kg/m
anodized
aluminum
–40 °C to +85 °C
DC 20 to 28 V
< 0.5 V
pp
< 90 mA
< 3 A/0.5 ms
UL authorization
File No.
E227256
The CE Mark verifies
that our products meet
the requirements of
EC Directive
8.3

Control signals

IInterface
RS 485/422
Clock input
+Clk, –Clk
(via optical coupler)
Clock frequency max. 1000 kHz
Output data
24 or 25 bit serial
Position information +Data, –Data
8.4

Connection to processor

+Clk, –Clk, +Data, –Data, 24 V,
GND
Cable, twisted-pair, shielded
max. length 400 m, Ø 6 to 8 mm
The clock frequency t is a function
of the cable length:
Cable length
Clock frequency
< 25 m
< 1000 kHz
< 50 m
< 500 kHz
< 100 m
< 400 kHz
< 200 m
< 200 kHz
< 400 m
< 100 kHz
Table 8-1: Clock frequency
Emission tests:
RF Emission
EN 55011 Group 1, Class A+B
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4
english
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl5-p-5500-2 serieBtl5-p-4500-1 serie

Tabla de contenido