8. FAULT DIAGNOSIS
Refer to tool instruction manuals for further fault diagnosis. The following faults relate only to the tools specified in this
manual.
SYMPTOM
Placing tool will not operate
Sensitive nose equipment does not
function
POSSIBLE CAUSE
Inoperative air supply
Damaged sensitive nose equipment
seals
Damaged air line in sensitive nose
equipment
Spring stuck
Damaged O-rings
REMEDY
Check air supply
Replace O-Rings in sensitive nose equip-
ment
Replace pneumatic tube as necessary
Check spring 9
Replace O-Rings in sensitive nose equip-
ment
E N G L I S H