Descargar Imprimir esta página

VITO Pro Power VICSOS50A Manual De Instrucciones página 38

Publicidad

Idiomas disponibles

Idiomas disponibles

After carrying out all the assembly and installation
procedures, the compressor is ready to run. The start-up
procedure should be carried out as soon as the compressor
is installed and in the following order:
1. Plug in the power cord;
2. Pull up the emergency stop switch (14) to start the
compressor motor;
- The compressor motor will run until the tank is
completely full. When the tank reaches its maximum
pressure, set on the pressure switch (15), the motor
switches off automatically.
- As soon as the motor shuts down, the compressed air
accumulated in the discharge pipe between the
compressor pump and the check valve is released. This
is the necessary condition to prevent to motor from
restarting under stress. This prevents motor damage
and extends its service life.
3. Press down the emergency stop switch to stop the
motor and prevent it from starting automatically;
4. Unscrew the drain plug (10), to empty condensed water
inside the tank;
5. After all the condensed water has come out, screw the
oil drain plug;
6. Connect the air blow guns or compressed air tools, in
the outlet valves with quick-release coupling (12);
7. Pull up the emergency stop switch so that the
compressor is ready to start;
- When the compressor is switched on, if the pressure
in the air tank is lower than the minimum pressure set
on the pressure switch, the motor starts immediately.
8. Check the pipes or couplings/fittings for air leaks. If you
do not have any tools or equipment attached to the
compressor or in the supply network and the
compressor starts up systematically, there is leakage.
The automatic operation of the compressor is controlled by
a pressure switch (15). The compressor starts when the
minimum pressure (6 bar) is reached and stops when the
maximum pressure is reached, as long as the emergency
stop switch is pulled upwards.
Do not adjust factory set pressure. They shall not be
changed.
The emergency stop switch attached to the pressure switch
enables the compressor to be stopped whenever the user
wishes or in the event of an emergency.
The safety valve or pressure relief valve (13) is set to trip
according to the permitted pressure of the air receiver tank
(7). If for some reason the permitted tank pressure is
reached and the motor does not stop, the safety valve
should open. It is not allowed to adjust the safety valve or
remove the plastic seal.
The outlet pressure in the outlet valves with quick-release
coupling can be adjusted in the outlet pressure regulator.
1. To adjust the outlet pressure, turn the pressure regulator
(11) clockwise to increase and counterclockwise to
decrease the pressure
After each use, unscrew the tank drain plug, to drain the
pressure regulator.
.

Publicidad

loading