1.
SAFETY INFORMATION
Read the following safety information carefully before attempting to operate or service the meter.
Use the meter only as specified in this manual:
• Environment conditions
1. Altitude lower than 2000 meters
2. Relatively humidity ≤90%RH
3. Operation Ambient 0~40°C
• Maintenance & Clearing
1. Repair or servicing not covered in this manual should be performed by qualified personnel.
2. Periodically wipe the case with a dry cloth. Do not use solvents or eradicator on this instrument.
Safety symbols
•
•
Comply with EMC
2. FUNCTIONS DESCRIPTION
This Sound Level Meter is designed for noise project; quality control; illness prevention and cure and all
kinds of environmental sounds measurement. It is applied to the sounds measurement at factory; school;
office; traffic access and household, etc.
• This unit confirms to the IEC61672-1 CLASS2 for Sound Level Meters.
• MAX & MIN measurements
• Over range display
• Under range display
• A & C Weighting
• FAST & SLOW response
• Analog AC/DC outputs for connection to frequency analyzer or X-Y shaft recorder
3. Specifications
Standard applied
IEC61672 -1 CLASS2
Accuracy
±1.4dB
Frequency range
31.5HZ ~ 8KHZ
Dynamic range
50dB
Memory
32700
Level ranges
LO:30dB~80dB
Med
50dB~100dB
Hi
80dB~130dB
Auto
30dB~130dB
Frequency weighting
A/C
Time weighting
FAST ( 125ms ), SLOW ( 1s )
Microphone
1/2 inch electret condenser microphone
Sound level meter with datalogger / English
1