Cleaning and maintenance
7
Cleaning and maintenance
!
WARNING! Electrocution hazard
Failure to obey this warning could result in death or serious injury.
Always disconnect the device from the power supply before you
clean and service it.
A
NOTICE! Damage hazard
Never clean the cooling device under running water or in dish
water.
Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the cooling device.
➤ Occasionally clean the cooling device interior and exterior with a damp
cloth.
➤ Ensure that the air inlet and outlet vents on the cooling device are free of
any dust and dirt, so that heat can be released and the cooling device is
not damaged.
8
Troubleshooting
Problem
Device does not
function, LED does
not glow.
The device does not
cool (plug is inserted,
"POWER" LED is lit).
The device does not
cool (plug is inserted,
"POWER" LED
flashes orange, dis-
play is switched off).
24
Possible cause
No voltage present in
the connected power
outlet.
One of the device
fuses is defective.
Defective compressor. ➤ This can only be repaired by an
Battery monitor is set
too high.
Battery voltage is too
low.
ICF18, ICF32, ICF40, ICF60, ICF80DZ
Remedy
➤ Plugged in DC power outlet: In
most vehicles the ignition must be
turned on before power will be
supplied to the DC power outlet.
➤ Replace the defective device fuse,
see chapter "Replacing the
device DC fuse" on page 23.
authorized repair center.
➤ Select a lower battery monitor set-
ting.
➤ Test the battery and charge it as
needed.