forbidden to clean objects placed directly in the tank; this can damage the tank. The greater
the number of items in the basket, the less eff ective the cleaning will be. It is not stack items
to be cleaned. It is advisable to leave plenty of space between objects for a better cleaning
eff ect. It is forbidden to place objects with small ends or objects with sharp edges that could
move outside the basket during cleaning and damage the tank. The unit should only be used
with the lid on, this will prevent accidental splashes and reduce fl uid evaporation. The product
must be kept under supervision at all times during operation.
NOTE! Do not open the drain valve while the product is in operation. Do not allow fl uid to spill
on the power cord, housing and controls of the unit, this may cause damage to the unit and/
or electric shock. Before adding or removing items from the basket and while removing fl uid
from the tank, unplug the unit from the power supply, wait for the cleaning fl uid and the unit
housing to cool down completely.
PRODUCT OPERATION
Product installation
The product must be unpacked by removing all packaging elements. It is recommended to keep the packaging, as it can be helpful
for further transport and storage of the product.
Place the unit on a fl at, hard and clean surface in a location that provides adequate ventilation. Ensure that the drain valve lever
is in the closed position – perpendicular to the tap (II). Carefully fi ll at least half of the tank with the cleaning fl uid. Place the items
to be cleaned in the basket. In the next step, carefully immerse the basket with the items in the cleaner's tank. The cleaning fl uid
should cover the object, but it should not exceed the top edge of the basket placed in the tank. Once the items have been placed
in the basket and the cleaner has been fi lled with fl uid, cover the tank with the lid. The cleaner should only be used with the lid on,
this will prevent accidental splashes and reduce fl uid evaporation.
Power supply connection
Check that the tool switch is in the off position – O. Connect the power cord to the port at the back of the housing (III). The plug has
such a shape that it can be connected in one correct way only. Connect the other end of the power cord plug to the mains socket.
Switch the device on by moving the power switch to the on position – I.
Control panel
The product is equipped with a control panel that allows the setting of operating parameters (IV).
On the left-hand side is the fl uid heating settings panel:
- display "Set °C" – set fl uid heating temperature,
- display "°C" – current fl uid temperature (approximate),
Light marked with a thermometer symbol – heating on/off ,
the "+" button – increasing the temperature,
"-" button – decreasing temperature,
warm-up button.
On the right-hand side is the ultrasonic operation panel:
Light marked with ultrasound symbol – ultrasound on/off
"MIN" display – minutes,
"SEC" display – seconds,
"+" button – increasing the time,
"-" button – decreasing time,
ultrasound button.
Setting the fl uid warm-up temperature/starting the warm-up
To set the preheat temperature, switch the appliance on by turning the power switch to the on – I position. Use the temperature
increase or decrease buttons on the preheat panel to set the temperature between 0 ~ +80°C. During setting, the temperature
value will change on the display. The fl uid will only be heated if the set temperature is greater than the current fl uid temperature.
The heating will start when the heat button is pressed. The display of the current temperature will start to fl ash, this means that
the fl uid heating process is on. The preheat indicator light will illuminate when the heater is activated. When the set temperature
is reached, the heater light will go out. The unit will automatically start and stop the heater to maintain the set temperature. The