Index Description
P66
Valve frequency
Non-return valve (clapet)
P67
opt.
P68
Flue parameter
Heating hysteresis after
P69
ignition
Notes:
1. The Maximum Power parameter can also be modified in Test Mode.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to
exit the card Service Menu, or exiting occurs automatically after 15 minutes.
"In" - Information Menu
12 pieces of information are available.
Press the Heating buttons to scroll the list of information in increasing or decreasing order. Press
the DHW buttons to display the value.
Index
Description
t01
NTC Heating sensor (°C)
t02
NTC Return sensor (°C)
t03
NTC DHW sensor (°C)
t04
NTC External sensor (°C)
t05
NTC Fume sensor (°C)
F06
Actual fan rpm
L07
Actual burner power (%)
F08
Actual DHW draw-off (l/min/10)
Actual system water pressure (bar/10)
P09
P10
Actual modulating pump speed (%)
P11
Burner operating hours
F12
Flame status
Notes:
1. In case of damaged sensor, the card displays hyphens.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to
exit the card Service Menu, or exiting occurs automatically after 15 minutes.
"Hi" - History Menu
The card can store the last 8 faults: the History datum item H1 represents the most recent fault
that occurred, whereas the History datum item H08 represents the least recent.
The codes of the faults saved are also displayed in the relevant menu of the Remote Timer Con-
trol.
Press the Heating buttons to scroll the list of faults in increasing or decreasing order. Press the
DHW buttons to display the value.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to
exit the card Service Menu, or exiting occurs automatically after 15 minutes.
"rE" - History Reset
Press the Winter/Summer/Off-On button for 3 seconds to delete all faults stored in the History
Menu: the card automatically exits the Service Menu, in order to confirm the operation.
Press the Reset button for 10 seconds to exit the card Service Menu, or exiting occurs automati-
cally after 15 minutes.
278
Range
0 - 3
0 - 1
0 ÷ 10 (modify according to flue table)
6 ÷ 30 °C
Range
0 ÷ 125 °C
0 ÷ 125 °C
0 ÷ 125 °C
+70 ÷ -30°C (negative values flash)
0 ÷ 125 °C
00 ÷ 120 x100RPM
00%=Min., 100%=Max.
00 ÷ 99 l/min/10
00 = With Pressure switch open,
12 = With Pressure switch closed, 00-99 bar/10 with
Pressure transducer
00 ÷ 100%
00 ÷ 99 x 100 hours
-- ÷ 255