6.- Selecting the operating mode.
6.1.- Automatic/Semi-automatic Cycle:
Automatic Cycle (DIP 4 ON).
Start button command – Door opens – Wait time with door open (the time can be adjusted using the timer N ) – Door closes.
If the start button is pressed or the photocell is activated during the wait time, the wait time will restart.
Semi-automatic Cycle (DIP 4 OFF).
Start button command – Door opens – Start button command – Door closes.
6.2.- Community/Step-by-Step Functions:
Community Function (DIP 3 OFF).
One start command opens the door and no more start commands will be accepted while it is opening.
Step-by-Step Function (DIP 3 ON).
One start command opens the door, a second start command stops it, a third start command closes it and a fourth start
command, if given during the closing manoeuvre, stops the door and reverses its travel until it reaches door open position.
6.3.- Optional Automatic:
In combination with DIP 4 ON.
-Optional automatic (DIP 5 ON)
if "Start" is received during the wait time, the door will close immediately.
-No optional automatic (DIP 5 OFF)
if "Start" is received during the wait time, the wait time is reset.
7.- Radio programming (for 433 Mhz Erreka RSD-001 trinary code only)
Radio programming must be done with the door closed.
The radio recordings for pedestrian and total opening are independent, and they may even correspond to different controls with
different codes.
7.1.- Total opening:
-Turn DIP 1to ON.
-Turn DIP 4 to ON. The memory is now open.
-Select the code on the control and press the channel to be recorded. LED DL2 will begin to flash.
-Turn DIP 4 to OFF.
-Turn DIP 1 to OFF.
7.2.- Pedestrian opening:
-Turn DIP 1to ON.
-Turn DIP 6 to ON. The memory is now open.
-Select the code on the control and press the channel to be recorded. LED DL2 will flash.
-Turn DIP 6 to OFF.
-Turn DIP 1 to OFF.
When the control code has been recorded, you will need to turn the switchboard off and on again
8.- Selecting the flashlamp operating mode.
8.1.- Warning Function.
Turn DIP 2 of selector G to ON. The flashlamp will light up for 3 seconds before the manoeuvre begins.
8.2.- Lamp output.
-Turn DIP 6 of the selector to ON. The lamp output is intermittent, and so a normal lamp can be used for the flashing function.
-Turn DIP 6 of the selector to OFF. The output is continuous, and so a flashlamp is needed.
29