FIG. 19
CIRCUIT BREAKERS
The Machine is equipped with (4) circuit breakers to
protect machine from damage.
If circuit breakers should trip, the breakers will not
reset immediately upon tripping. Determine reason
why breaker tripped, allow motor to cool and reset.
Brush motor circuit breakers will trip due to excessive
overload on pad. Reduce pad pressure or replace pad
if breaker should trip. Brush motor circuit breakers
(15amp) are located near charger plug.
The main (10amp) and drive/vacuum (35amp) circuit
breakers are located at rear of machine (Figure 20).
FIG. 20
Speed Scrubt 2401/2601 (08–01)
Home
Find... Go To..
DRAINING TANKS
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
DRAINING RECOVERY TANK
When finished scrubbing or when refilling solution
tank, recovery tank should be drained and cleaned.
ATTENTION: If recovery tank is not drained
before refilling, foam or water will enter float
shut-off screen and vacuum motor damage will
result.
1. Remove drain hose from holder, position hose
over floor drain and twist off drain hose plug. To
completely drain recovery tank, hinge open tank
and flip up tank support stand to rest tank on
(Figure 21).
NOTE: If using a bucket to drain machine, do not use
same bucket for filling solution tank. This will prevent
possible solution line clogs.
FIG. 21
2. Clean recovery tank after each use. Use a hose to
rinse out tank. Be careful not to spray water into
float shut–off screen.
3. Replace drain hose plug tightly after draining.
DRAINING SOLUTION TANK
To drain leftover cleaning solution from solution tank,
perform the following steps:
1. Pull clear hose off hose barb at rear of machine
and drain solution into floor drain or bucket
(Figure 22).
OPERATION