Descargar Imprimir esta página

Rothenberger RO BC 18 AMPShare Instrucciones De Uso página 16

Ocultar thumbs Ver también para RO BC 18 AMPShare:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
When there is no battery connected, the continuous light of the battery charge indicator signals
that the mains plug is plugged into the plug socket and that the charger is ready to be used.
Continuous light red temperature monitoring indicator (3):
The continuous light of the red indicator signals that the temperature of the battery is outside of
the permitted charging temperature range (0–45 °C).
The charging process begins as soon as the permitted temperature range has been reached.
Flashing light red error indicator (3):
The flashing light of the red indicator signals that the charging process has been interrupted by a
different fault see „ Troubleshooting".
3.4
Wall mounting
 Pull the plug out of the socket before carrying out any work on the charger.
4
Troubleshooting
Symptom
Battery is not being
charged and the red
temperature monitor-
ing/error indicator is
flashing red
Battery is not being
charged and the indica-
tor is lit up red
None of the indicators
are lighting up, battery
will not be charged
5
Care and Maintenance
Repairs to the charger must only be carried out by qualified electricians.
If the mains connection cable of this tool is damaged, in order to prevent endangering personnel
and property it must be replaced by the manufacturer, or the Customer Service of the manufac-
turer, or a similarly qualified person.
Occasionally clean the ventilation slots and the terminals on the battery using a soft brush that is
clean and dry.
12
The charger can be used either free-standing (for use on a desktop)
or mounted on the wall.
When affixing to the wall: Drill 2 holes, leaving a clearance of 72
mm. To secure it, use round-head screws with a diameter of 5 mm
to max. 6.5 mm.
Possible Reason
The charger has identi-
fied an internal error
Battery is not correctly
inserted
The battery contacts
and charging contacts
are dirty
Battery defective
Akkutemperatur außer-
halb des zulässigen
Ladetemperaturbereichs
Plug socket, mains
cable or battery charger
defective
Mains plug of the bat-
tery charger is not
(correctly) plugged in
ENGLISH
Solution
Ensure that all batteries are fully
inserted. Remove the mains plug and
reinsert. If the error occurs again,
have the charger checked by an
authorised after-sales service centre
Insert the battery into the charger
correctly
Clean the battery contacts and
charging contacts; e.g. by inserting
and removing the battery several
times
Replace the battery
Wait until the battery temperature is
back within the permitted charging
temperature range (0–45 °C)
Check the mains voltage. If neces-
sary, have the charger checked by
an authorised after-sales service
centre
Plug the mains plug (fully) into the
plug socket