6. Programming the operator
6.1 Preparing
99 11
- -
6.2 Setting open and close position.
p1
Op
Op
C l
C l
Op
C l
- -
6.1.1 Keep trolley locked, pull and push the door by hand, make
sure the trolley connects with the shuttle.
6.1.2 Turn on the power, the courtesy light in on for several
seconds, at the same time, the LED displays the number from 99
to 11.
Then the operator turns to stand by situation.
6.1.3 At last, it displays "- -".
6.2.1 Press and hold SET until it displays "P1".
6.2.2 Press SET, it displays "OP".
6.2.3 Then press and hold UP, it ashes "OP".
6.2.4 When the door has reached the open position, press SET, it
displays "CL".
6.2.5 Then press and hold DOWN, it ashes "CL". When the door has
reached the closed position, press SET.
6.2.6 The door opens and closes automatically to map the open and
close sensitivity force requirements.
6.2.7 It displays "- -" to show setting is complete.
6
Code: SC1800