Descargar Imprimir esta página

Accessmatic Scorpion 1800 Manual De Instalación página 37

Publicidad

Idiomas disponibles

Idiomas disponibles

8 Owners´ guide
8.1 Attention in use
8.1.1 At the rst time using the door, please test the driving system to see if it moves well. (Test method: unlock the trolley,
pull and push the door by hand.)
8.1.2 Connected with the appropriated power and socket by professionals and connected the earing wire with earth.
8.1.3 Using the transmitter in your right sight, do not stand or walk under a moving door. The transmitters should be out of
reaching of children.
8.1.4 Make sure the door out o
8.1.5 Check al least twice a year to make sure the door is perfectly balanced and that all working parts are in good working
condition. Adjust the tensile force chain. Add suitable amount of lubricate to the active system.
8.2 Examination guide
Problem
The chain is noisy.
The motor does not work.
After setting open and close
positions, the motor does not work.
The door can´t be closed.
The wall button works well, but the
transmitter doesn´t work.
Transmitter distance is too short.
re, moisture, electromagnetism and some other places.
Causes
The chain is too loose.
The socket is not well connector the fuse is
broken.
The screws of xing the hall components are
loose or program mistakes.
Photobeam functions works.
No transmitter learning or transmitter battery
is power o .
The transmitter battery is nearly power o .
13
Solution
Adjust nut – m8 referring to gure 6
on page 5.
Check the socket or replace the fuse.
Tighten the screws or open resetting
open and close positions.
Cancel the photobeam function,
referring to 6.6.
Code referring to 6.4 or change
new transmitter battery.
Change new battery.
Code: SC1800

Publicidad

loading

Este manual también es adecuado para:

Sc1800