Conductor cross sections for stan-
dard inputs and outputs (connec-
tion element 4), optional inputs and
outputs (except for relays and solid
state relays), RS485 interface
Wire or stranded wire
(without ferrule)
Stranded wire with ferrule
Stripping length
5.8
Environmental influences
Ambient temperature range
Storage
Operation
Site altitude
Climatic environmental influences
Resistance to climatic conditions ≤ 90 % rel. humidity without condensation
Storage
Operation
Vibration
Amplitude
Acceleration
Shock
Peak acceleration
Shock duration
Electromagnetic compatibility
(EMC)
Interference emission
Interference immunity
a
The product is suitable for industrial use as well as for households and small businesses.
b
With Ethernet interface: Class A – only for industrial use –
2
Min. 0.2 mm
, max. 1.5 mm
Without plastic collar: min. 0.25 mm
With plastic collar: min. 0.25 mm
10 mm
-30 to +70 °C
-10 to +55 °C
Max. 2000 m above sea level
According to DIN EN 60721-3 with extended temperature range
According to class 1K2
According to class 3K3
According to DIN EN 60068-2-6, table C.2
0.15 mm from 10 to 58.1 Hz
2
20 m/s
from 58.1 to 150 Hz
According to DIN EN 60068-2-27, table A.1
2
150 m/s
11 ms
According to DIN EN 61326-1:2013
a, b
Class B
Industrial requirements
5 Technical data
2
2
, max. 1.5 mm
2
2
, max. 0.75 mm
2
35