OPERATION
Anti-collision sensitivity setting
Press the
and
access to the anti-collision menu setting. There are three levels of sensitivity:
A-0 OFF - no Anti-collision
A-1 Low sensitivity
A-2 Medium sensitivity
A-3 Strong sensitivity
With each operation described above, you switch through the different
anti-collision modes in sequence.
The mode displayed is the one set. Saving is not necessary.
TROUBLESHOOTING
Error
AF5 is shown on the LED Display.
The table won't move and E01 or E02 is
shown on the LED display.
The table does not go down, although the
key is pressed continuously.
buttons simultaneously for 5 seconds. Then you have
Solution
A reset must be carried out. Press the
lowest position. Press the button again for
5 seconds until RST appears in the display
and the table is raised a little again. The
reset has now been successfully comple-
ted.
Keep the table connected to power and
do not press any button on the control
panel for at least 18 minutes.
Check all cable connections and make
sure that each cable is correctly connec-
ted. Then disconnect the desk from the
power for at least 10 seconds. Once you
reconnect the desk to the power the LED
display should come on and you should
carry out the first solution procedure (re-
set) from the table.