TROUBLESHOOTING
Error
The table does not go up, although the
key is pressed continuously.
After continuous operation, the table can
no longer be moved.
Error code „HOT" is shown in the LED dis-
play.
The table doesn't reach its maximum or
minimum height.
The error code E09 is shown in the LED
display.
The table has been moved unevenly (the
tabletop is crooked), the columns have
jammed.
The error code E23 appears in the LED
display.
Solution
Check all cable connections and make
sure that each cable is correctly connec-
ted. Also check if the table is connected
to the power supply. Make sure that the
table is not overloaded (max. load 125 kg).
As soon as the table has been in conti-
nuous operation for more than 2 minutes,
it switches to overheating protection. This
protection mode lasts approx. 18 min. If
the table still cannot be moved after 18
minutes, remove the table from the pow-
er supply for 10 minutes and then try it
again.
Press the 3 and M buttons simultaneously
for three seconds. After a beep sounds,
the table is reset back to the factory set-
tings.
Carry out a reset of the system described
in the first solution procedure from the
table.
The motor has a fault. Check whether
the cable connections M1 and M2 are
correct. Reconnect the cables. If this
doesn't fix the error, contact a profes-
sional, Your dealer or celexon directly
(info@celexon.co.uk).