OPERATING INSTRUCTION
Mounting with the reusable double sided gel pad
(For mounting to glass, metal, marble, tiles, wood, plastic and other smooth surfaces.)
1
2
1
2
1) Install the bracket accessory on the back of bracket and remove the release liner of gel pad.
2) Stick the bracket on the the desired surface.
3) Place the laser level onto the bracket and use the bubble levels to level the unit.
Note:
• The gel pad may be washed and used repeatedly. To maintain good adhesion, wash the gel pad
frequently. Make sure the gel pad is cleaned of any dust or debris before your operation.
• Do not use the gel pad to fasten onto the wall if the wall surface is loose or wet.
• Always keep the target wall surface clean.
• Remove from the wall slowly after using, any residue of the gel pad remaining on the wall can be
cleaned by rolling the gel pad over the residue.
• Both side of bracket accessory all can be installed on the back of bracket, when one side with gel pad
not be used, can keep this side be installed interiorly for gel pad is cleaned.
DETECTOR
Stud detection
Detecting elements for wood and metal studs and AC wire are located in the lower part of the unit.
For stud detection through up to 3/4 inch (19mm) thick drywall.
1
2
ON
ON
3
3
ON
9
OPERATING INSTRUCTION
4
5
CALIBRATING...
READY
1) Hold unit straight up and down and place flat against wall (Picture 1)
2) Press in and hold DETECTOR button. LCD screen (Picture 4) will light and detector will run
initialization process.
3) READY message will appear on LCD screen (Picture 5), two LED lights will turn green and the unit
will beep once to indicate it is calibrated and ready for detection.
4) Slide unit slowly (Picture 2), horizontally across surface of wall without lifting or tilting. When the left
or right LED light turn red, slow down and keep sliding until CENTER message appears (Picture 6),
beep sounds and another LED turns red.
5) At the same time, the top laser line beam also be projected on the wall and indicate the center of
stud (Picture 3).
AC Wire Sensing
Test on a known "live" AC wire before each use. For AC Detection up to 1-1/2 inches (38mm) from the
surface. The sensor detects AC voltage and will identify only live wires. AC voltage detection feature
works continuously when detecting studs. It assists in identifying when the sensor is near live AC
wiring and detector button is depressed. Once AC voltage has been detected AC wire indicator
will appear on the LCD screen. If the unit is calibrated close to AC wire, it may decrease AC wiring
sensor sensitivity. Static charge may spread detection 12 inches (30.4cm) on both sides of wire.
CHARGING
1) Connect Type-C cable wire properly to charge the laser level. Battery indicator
charging.
2) When Battery indicator stop flashing
CARE AND MAINTENANCE
This product has been designed to be a low-maintenance tool. However, in order to maintain its
performance, you must always follow these simple directions:
• Avoid exposing the tool to shock, continuous vibration or extreme hot or cold environment.
• Always store the tool indoors.
• Always keep the tool free of dust and liquids. Use only a clean soft cloth for cleaning. If necessary,
slightly moisten the cloths with pure alcohol or a little water.
• Do not disassemble the tool, this will expose the user to hazardous radiation exposure.
• Do not attempt to change any part of the tool.