ENGLISH
Electrical system data
System voltage
Starting battery
Hydraulic system data
Maximum drive system pressure
Maximum accessory system pressure
Hydraulic system oil (at ambient temperature above 10 °C)
NOTE
If the machine is to be used at ambient temperatures below 10 °C, the oil should be replaced with equivalent oil having a
viscosity of 32 cSt. For temperatures below 0 °C, use oil with lower viscosity.
(****)
See the hydraulic system oil technical data and reference data tables below.
SPECIFICATIONS
AGIP ARNICA
Viscosity at 40 °C
Viscosity at 100 °C
Viscosity index
Flash point COC
Pour point
Density at 15 °C
Climate control system data (optional)
Gas type
Gas quantity
Camera kit description (optional) (*)
Make
Type
14
INSTRUCTIONS FOR USE
/
mm
mm
/
°C/°F
°C/°F
kg/l
33019745(2)2009-12
46
32
/s
45
32
2
/s
7.97
6.40
2
150
157
215/419
202/396
-36 /- 32.8 -36/-32.8
0.87
0.865
RS 501
Values
12 V
12 V – 80 Ah
Values
3,626 psi (250 Bar)
1,740/2,901 psi (120/200 Bar)
AGIP Arnica 46 (****)
REFERENCE DATA
ISO-L-HV
ISO 11158
AFNOR NF E 48603 HV
AISE 127
ATOS Tab. P 002-0/I
BS 4231 HSE
CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA
22, 46, 68)
EATON VICKERS I-286-S3
EATON VICKERS M-2950
DIN 51524 t.3 HVLP
LAMB LANDIS-CINCINNATI P68, P69, P70
LINDE
PARKER HANNIFIN (DENISON) HF-0
REXROTH RE 90220-1/11.02
SAUER-DANFOSS 520L0463
Values
Reclin 134a
1.8 lb (0.8 kg)
Values (*)
Continental VDO -
LCD 5" color monitor
Infrared color camera