SWITCH INPUT WIRING (E1–8)
Connecting the TVMS Rogue to switches.
Read the following important safety instructions (page 4): 25,
POWER INPUT CABLE WIRING (A)
Connecting the TVMS Rogue to the auxiliary battery.
Read the following important safety instructions (page 4): 21, 22, 23, 24,
Connect as shown in 'Wiring Diagram — Basic Install' (page 5).
POWER INPUT CABLE SIZING
Purchase the correct cable size needed for your installation. Make sure you purchase good-quality cable with a suitable temperature
rating for your installation.
Note: Wiring components including fuses, lugs, extension cables and consumables are not supplied.
The cable between the TVMS Rogue and auxiliary battery must a large enough gauge to prevent excessive voltage drop over its length.
As voltage drop occurs between battery positive and ground, the total Cable Install Length of Positive and Negative cable combined
must be considered. Refer to the Cable Size Selection Table for the correct cable size for your cable length.
Power Wiring Loom
Cable Install Length*
< 2 m (< 6'8")
2 – 5 m (6'8" – 16')
5 – 12 m (16' – 40')
* Cable Install Length refers to the total length of the cables (positive and negative combined) from the auxiliary battery positive terminal to the grounding point.
FUSING
A 50 A MIDI fuse is required to protect the Power Input cable.
(supplied)
Cable Size Selection Table
30
25
Negative Cable
(not supplied)
Positive Cable
(not supplied)
mm²
≥ 7.7 mm²
≥ 13.5 mm²
≥ 20.2 mm²
Total Cable Length
AWG / BAE / B&S
≈ 8
≈ 6
≈ 4