English
Protective
equipment
Earth fault and
residual current
monitoring
DC circuit breaker
DC polarity
protection
Overvoltage
arrester DC input
Overvoltage
category (in
accordance with
IEC 60664-1)
Protection class
(according to IEC
62103)
Conformity
Satisfied
requirements/available
safety declarations
Interference emission /
resistance (EMV)
Equipment reliability
Conformity and
approval
Radio regulations
Connection options for
ripple control receiver
Bosch Power Tec GmbH
BPT-S 3
BPT-S 3.68
Integrated (insulation measurement and universal RCDs in accordance with EN
62109-2)
Integrated (electro-mechanical)
Integrated (automatic measurement of the DC voltage prevents connection in
case of polarity reversal)
Varistores class 3
III (AC-side) / II (DC-side)
Class I
Class I
BPT-S 3
BPT-S 3.68
VDE-AR-N 4105:2011, VDE-0126-1-1:2013
DIN EN 61000-6-2:2006 + A1:2011, DIN EN 61000-6-3:2011
DIN EN 62109-1:2011, DIN EN 62109-2:2012, EN 60950-1:2011
CE
CE
ETSI EN 301489-1:2011, ETSI EN 301489-3:2002, ETSI EN 300330-
2:2010, ETSI EN 302291-2:2005
combined with optional accessories
BPT-S 4
Class I
BPT-S 4
CE
Bosch BPT-S 3 / 3.68 / 4 / 4.6 | Operating manual
Specifications | 113
BPT-S 4.6
Class I
BPT-S 4.6
CE