MAINTENANCE AND DIAGNOSIS OF FAILURES

1

MAINTENANCE

Before
carrying
operation, disconnect the device from the
power supply.
Frequently check the installation in order to
discover any imbalance or sign of deterioration
or wear. Do not use the device if any repair or
adjustment is necessary.
A record of all repairs and maintenance operations
must be kept. The owner of the facility must keep
these records safe.
Every three months
1 Clean and lubricate the moving parts so as not to
increase the effort of the operator
2

FAILURE DIAGNOSIS

Problem
The barrier does not make
any movement when a key
command is given
The barrier does not open
The
barrier
completely close (or open)
3

SPARE PARTS

If the device needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
4

SCRAP

The device, up until the end of its useful life,
must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner possible accidents and damage to
adjacent facilities will be avoided.
42
Installation Guide
out
any
maintenance
Cause
Absence of system power supply
voltage
Main switch SW1 in "OFF"
F1 blown
Cover open
Command devices defective
Excess load on the barrier
Barrier imbalanced
Th e saf e ty de vic e d e te ct s a n
obstacle
cannot
Limit switches poorly regulated
Opening or closing time is lower
than required
Every six months
1 Check that the command and safety devices, as well
as their installation, have not suffered any damage
from the weather or external agents
2 Check the operation of the limit switches and the
flashing light
3 Check the tautness of the toothed belt
4 Check manual operation
Every year
1 Check the torque of the screws and balancing
spring
2 Check the clearance between the screw and the nut
Solution
Reestablish the power supply
Place SW1 in "ON"
Replace using another fuse of the same
value and investigate the cause of the
failure
Close the cover
Check the respective manuals
Remove the excess load
Balance using the spring tightener or by
replacing the spring
Remove the obstacle and try again
Regulate correctly
Adjust the T.C. or T.A. potentiometers
Use only original spare parts.
}
The device must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying of the different materials in line with their
nature. NEVER deposit it in domestic rubbish or in
landfills which are not suitably controlled, as this will
cause environmental contamination.