Descargar Imprimir esta página

Electrolux KGS6404SX Manual De Instrucciones página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING!
Make sure to place the gasket exactly in
the original position.
WARNING!
Make sure the flame does not go out
when you quickly turn the knob from the
maximum position to the minimum
position.
3.5 Electrical connection
• Make sure that the rated voltage and type
of power on the rating plate agree with the
voltage and the power of the local power
supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a correct
plug which can hold the load that the
rating plate rates. Make sure that you
install the plug in a correct socket.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to the
mains plug after the installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• There is a risk of fire when the appliance
is in connection with an extension cable,
an adapter or a multiple connection. Make
sure that the ground connection agrees
with the standards and regulations.
• Do not let the power cable to heat up to a
temperature higher than 90° C.
To prevent contact between the cable and the
appliance below the hob use the clamps
which are on the side of the cabinet.
A
A. Rigid copper pipe or flexible pipe of
stainless steel
3.6 Connection cable
To replace the connection cable use only the
special cable or its equivalent. The cable type
is: H03V2V2-F T90.
Make sure that the cable section is applicable
to the voltage and the working temperature.
The yellow / green earth wire must be
approximately 2 cm longer than the brown (or
black) phase wire.
N
1. Connect the green and yellow (earth) wire
to the terminal which is marked with the
letter 'E', or the earth symbol
coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the letter 'N'
or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the letter
'L'. It must always be connected to the
network phase.
L
, or
ENGLISH
9

Publicidad

loading