AC input modes:
Count:
Counting and reset inputs
INP A:
AC/DC counting input
INP B:
AC/DC reset input
Cnt.Dir:
Counting and counting direction input
INP A:
AC/DC counting direction input
INP B:
AC/DC counting input
Main technical features:
Display:
LCD, 8 decades, height of the figures 8 mm.
Display range:
-9999999 ... 99999999
with leading zeros suppression.
Overflow: In case of a display range overflow, the
counter starts again from 0, but without
removing the leading zeros and activating
all decimal points.
In case of a display range underflow, the
counter starts again from 0 and displays the
minus sign, without removing the leading
zeros and activating all decimal points.
Keys:
Electrical locking of the reset key
Housing: Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22,2+
0,3 mm
x 45+
Mounting depth: approximately 48 mm
Weight:
approximately 50 g
Protection level:
IP65 on the front side
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1,5 mm2
3
0,6 mm
2 x 0,75 mm2
AWG 26-14
Up.Dn:
Differential counting input
INP A:
AC/DC subtracting counting input
INP B:
AC/DC adding counting input.
EMC:
Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2
Device safety:
Design to: EN61010 Part 1
Protection Class: 2
Application area: Soiling Level 2
Low Voltage Directive (for the AC models):
EN 61010 Part 1 ; overvoltage category 2,
contamination level 2
Power supply:
Non-replaceable lithium battery
(lifetime approximately, 8 years at 20°C)
Working temperature:
–10 ... +55 °C, relative humidity < 85%,
without condensation
Operating temperature:
–10 ... +60 °C
Storage temperature:
–20 ... +70°C
Altitude:
to 2000 m
Backlighting:
external electrical source
(24 V DC ±20 %, 50 mA)