WARNING
Please read and keep these instructions
before proceeding with the installation.
Safety Instructions
Installation needs to comply with state and local laws and regulations.
System must be installed indoors.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before the water enters the system.
Keep the system away from heat sources and direct sunlight.
This reverse osmosis system contains replaceable treatment components critical
for effective reduction of total dissolved solids. The product should be tested
periodically to verify that the system is performing satisfactorily.
This system is intended to be installed under a sink with access to cold tap water
and a waste water drain.
To prevent the possibility of electrical shock, be sure that all electrical appliances
and outlets are turned off at the circuit breaker before working in the cabinet area.
Please wear safety glasses to protect eyes when drilling.
Operational Parameters
Daily Production Rate: 54 GPD
Rated Capacity 1,360 litres
Operating Pressure: 275 - 550 KPa
Max Total dissolved solids 1500 mg/L
Before Installation
Inspect the system:
Please take all the components out of the box. Inspect all the parts and connection fittings carefully, make
sure that nothing was damaged during shipping. If any part is cracked or broken, please do not proceed
with the installation. Contact customer service for assistance.
Tools needed for Installation:
Electric drill
Drill bit:
6 mm for the waste water line
20 mm for the RO water faucet
Adjustable wrench
Philips screwdriver
Utility knife or scissors
PTFE Tape (often referred to as "plumber's tape" or "Teflon
Under Sink / Instructions
Maximum hardness 171 mg/l (10 gpg)
Chlorine < 2 PPM
PH 3-11
Turbidity 5 NTU max
Qualified Installers
Using a qualified installer is recommended.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the warranty.