  • Página 1 User manual CPE DIP SWITCH POE 24V WL-CPE2G24D-075 / WL-CPE5G24D-076 / WL-CPE5G24D-080...
  • Página 3 INDEX 1 Connection Diagram 1.1 Connection diagram between POE with the CPE 2. DIP Device instruction 3. Setting the signal strength 4. Questions & answers 5. DIP codes, segment and frequency...
  • Página 4 1. CONNECTION DIAGRAM Connection diagram between POE with the CPE POE port: connect the LAN1 or LAN2 port to the AP. LAN POE: connect to PC, camera, Switch or XVR. Notes 1. Both RJ45 ports (black and yellow) on the AP are LAN connections. 2.
  • Página 5 Keys 9 & 10: There are for point to multipoint functionality. It is possible to use up to 4 cameras with one dvr. Configure the DIP switches as follows: 1. From dvr / PC / switch, switches 9 and 10 should remain up. 2.
  • Página 6 3. SETTING THE SIGNAL STRENGTH If you want to change the settings of the AP. Follow the following settings. 1. Assign a static IP address to the PC in the same range as the AP: Note: The subnet mask must be “255.255.0.0” for IP “172.18.128.1”.
  • Página 7 Distance configuration: the default is two kilometers, it should be set according to your needs. (The same distance value must be set in the transmitter and receiver. Otherwise, a low-latency, low-ban- dwidth network connection will occur.) 4. QUESTIONS & ANSWERS Q1: What should be noted when setting the AP DIP switches? A1: Make sure the power is off Q2: How does the AP work without a dedicated power supply?
  • Página 8 Q8: After connecting the AP to the NVR, I am able to see the IP address of the camera, but no image. A8: Try changing the LAN port of the AP. If you are still having problems contact your dealer. Q9: What do the LEDs on the device represent? A9: Red: PWR: Power LED: it is on when the device is connected to the power supply.
  • Página 9 5. 128 PAIR CODES, SEGMENT AND FREQUENCY CA BE REFERRED TO THE FOLLOWING CHARTH Group 2-8 Dial IP Segment 5.8GHz IP Segment 2.4GHz n° 1 172.18.0.X 5160 172.17.0.X 2412 n° 2 172.18.1.X 5180 172.17.1.X 2417 n° 3 172.18.2.X 5200 172.17.2.X 2422 n°...
  • Página 10 n° 20 172.18.19.X 5825 172.17.19.X 2452 n° 21 172.18.20.X 5160 172.17.20.X 2457 n° 22 172.18.21.X 5180 172.17.21.X 2462 n° 23 172.18.22.X 5200 172.17.22.X 2412 n° 24 172.18.23.X 5220 172.17.23.X 2417 n° 25 172.18.24.X 5240 172.17.24.X 2422 n° 26 172.18.25.X 5745 172.17.25.X 2427 n°...
  • Página 11 n° 41 172.18.40.X 5160 172.17.40.X 2447 n° 42 172.18.41.X 5180 172.17.41.X 2452 n° 43 172.18.42.X 5200 172.17.42.X 2457 n° 44 172.18.43.X 5220 172.17.43.X 2462 n° 45 172.18.44.X 5240 172.17.44.X 2412 n° 46 172.18.45.X 5745 172.17.45.X 2417 n° 47 172.18.46.X 5765 172.17.46.X 2422 n°...
  • Página 12 n° 62 172.18.61.X 5180 172.17.61.X 2442 n° 63 172.18.62.X 5200 172.17.62.X 2447 n° 64 172.18.63.X 5220 172.17.63.X 2452 n° 65 172.18.64.X 5240 172.17.64.X 2457 n° 66 172.18.65.X 5745 172.17.65.X 2462 n° 67 172.18.66.X 5765 172.17.66.X 2412 n° 68 172.18.67.X 5785 172.17.67.X 2417 n°...
  • Página 13 n° 83 172.18.82.X 5200 172.17.82.X 2437 n° 84 172.18.83.X 5220 172.17.83.X 2442 n° 85 172.18.84.X 5240 172.17.84.X 2447 n° 86 172.18.85.X 5745 172.17.85.X 2452 n° 87 172.18.86.X 5765 172.17.86.X 2457 n° 88 172.18.87.X 5785 172.17.87.X 2462 n° 89 172.18.88.X 5805 172.17.88.X 2412 n°...
  • Página 14 n° 104 172.18.103.X 5220 172.17.103.X 2432 n° 105 172.18.104.X 5240 172.17.104.X 2437 n° 106 172.18.105.X 5745 172.17.105.X 2442 n° 107 172.18.106.X 5765 172.17.106.X 2447 n° 108 172.18.107.X 5785 172.17.107.X 2452 n° 109 172.18.108.X 5805 172.17.108.X 2457 n° 110 172.18.109.X 5825 172.17.109.X 2462 n°...
  • Página 15 n° 125 172.18.124.X 5240 172.17.124.X 2427 n° 126 172.18.125.X 5745 172.17.125.X 2432 n° 127 172.18.126.X 5765 172.17.126.X 2437 n° 128 172.18.127.X 5785 172.17.127.X 2442...
  • Página 17 INDICE 1 Diagramma di connssione 1.1 Schema di connessione tra POE con la CPE 2. Istruzioni dispositivo DIP 3. Impostazione della potenza del segnale 4. Domande & Risposte 5. Codici DIP, segmenti e frequenze...
  • Página 18 1. DIAGRAMMA DI CONNESSIONE Schema di connessione tra POE con la CPE Porta POE: collegare la porta LAN1 o LAN2 all’AP. LAN POE: collegare al PC ,telecamera, Switch o XVR. Note 1. Entrambe le porte RJ45 (nera e gialla) sull’AP sono connessioni LAN. 2.
  • Página 19 Tasti 9 & 10 : Sono per la funzionalità da punto a multipunto. E’ possibile utilizzare fino a 4 telecamere con un dvr. Configurare gli interruttori DIP come segue: 1. Da dvr / PC / switch, gli interruttori 9 e 10 dovrebbero rimanere alzati. 2.
  • Página 20 3. IMPOSTAZIONE DELLA POTENZA DEL SEGNALE Se si desidera modificare le impostazioni del AP. Seguire le seguenti impostazioni. 1. Assegnare al pc un indirizzo IP statico nella stessa portata dell’AP Nota: La subnet mask deve essere “255.255.0.0” per IP “172.18.128.1”. Note: Indirizzo Ip per i dispositivi 2.4 G è...
  • Página 21 Configurazione distanza: il valore predefinito è due chilometri, deve essere impostato in base alle proprie esigenze. (Lo stesso valore di distanza deve essere impostato nel trasmettitore e nel ricevitore. In caso contrario, si verificherà una connessione di rete a bassa latenza e larghezza di banda ridotta). 4.
  • Página 22 na immagine. R8: Provare a cambiare la porta LAN del AP. Se si riscontrano ancora problemi contattare il proprio rivenditore. D9: Cosa rappresentano i LED sul dispositivo? R9: Rosso: PWR: LED Power: è accesa quando il dispositivo è collegato all’alimentazione. Blu:WLAN: LED segnale Wifi.
  • Página 23 5. 128 COPPIE DI CODICI, SEGMENTO E FREQUENZA POSSONO ESSERE RIFERITI AL SEGUENTE GRAFICO Group 2-8 Dial IP Segment 5.8GHz IP Segment 2.4GHz n° 1 172.18.0.X 5160 172.17.0.X 2412 n° 2 172.18.1.X 5180 172.17.1.X 2417 n° 3 172.18.2.X 5200 172.17.2.X 2422 n°...
  • Página 24 n° 10 172.18.9.X 5825 172.17.9.X 2457 n° 11 172.18.10.X 5160 172.17.10.X 2462 n° 12 172.18.11.X 5180 172.17.11.X 2412 n° 13 172.18.12.X 5200 172.17.12.X 2417 n° 14 172.18.13.X 5220 172.17.13.X 2422 n° 15 172.18.14.X 5240 172.17.14.X 2427 n° 16 172.18.15.X 5745 172.17.15.X 2432 n°...
  • Página 25 n° 31 172.18.30.X 5160 172.17.30.X 2452 n° 32 172.18.31.X 5180 172.17.31.X 2457 n° 33 172.18.32.X 5200 172.17.32.X 2462 n° 34 172.18.33.X 5220 172.17.33.X 2412 n° 35 172.18.34.X 5240 172.17.34.X 2417 n° 36 172.18.35.X 5745 172.17.35.X 2422 n° 37 172.18.36.X 5765 172.17.36.X 2427 n°...
  • Página 26 n° 52 172.18.51.X 5180 172.17.51.X 2447 n° 53 172.18.52.X 5200 172.17.52.X 2452 n° 54 172.18.53.X 5220 172.17.53.X 2457 n° 55 172.18.54.X 5240 172.17.54.X 2462 n° 56 172.18.55.X 5745 172.17.55.X 2412 n° 57 172.18.56.X 5765 172.17.56.X 2417 n° 58 172.18.57.X 5785 172.17.57.X 2422 n°...
  • Página 27 n° 73 172.18.72.X 5200 172.17.72.X 2442 n° 74 172.18.73.X 5220 172.17.73.X 2447 n° 75 172.18.74.X 5240 172.17.74.X 2452 n° 76 172.18.75.X 5745 172.17.75.X 2457 n° 77 172.18.76.X 5765 172.17.76.X 2462 n° 78 172.18.77.X 5785 172.17.77.X 2412 n° 79 172.18.78.X 5805 172.17.78.X 2417 n°...
  • Página 28 n° 94 172.18.93.X 5220 172.17.93.X 2437 n° 95 172.18.94.X 5240 172.17.94.X 2442 n° 96 172.18.95.X 5745 172.17.95.X 2447 n° 97 172.18.96.X 5765 172.17.96.X 2452 n° 98 172.18.97.X 5785 172.17.97.X 2457 n° 99 172.18.98.X 5805 172.17.98.X 2462 n° 100 172.18.99.X 5825 172.17.99.X 2412 n°...
  • Página 29 n° 115 172.18.114.X 5240 172.17.114.X 2432 n° 116 172.18.115.X 5745 172.17.115.X 2437 n° 117 172.18.116.X 5765 172.17.116.X 2442 n° 118 172.18.117.X 5785 172.17.117.X 2447 n° 119 172.18.118.X 5805 172.17.118.X 2452 n° 120 172.18.119.X 5825 172.17.119.X 2457 n° 121 172.18.120.X 5160 172.17.120.X 2462 n°...
  • Página 31 INDICE 1 Diagrama de conexión 1.1 Diagrama de conexión entre POE con el CPE 2. Instrucciones del dispositivo DIP 3. Configurar la fuerza de la señal 4. Preguntas y respuestas 5. Códigos DIP, segmentos y frecuencias...
  • Página 32 1. DIAGRAMA DE CONEXIÓN Diagrama de conexión entre POE con el CPE Puerto POE: conecte el puerto LAN1 o LAN2 al AP LAN POE: conecta a PC, cámara, Switch o XVR. Notas 1. Ambos puertos RJ45 (negro y amarillo) en el AP son conexiones LAN. 2.
  • Página 33 Las teclas 9 y 10: Son para la funcionalidad punto a multipunto. Es posible utilizar hasta 4 cámaras con un dvr. Configure los interruptores DIP de la siguiente manera: 1. Desde dvr / PC / switch, los interruptores 9 y 10 deben permanecer activados. 2.
  • Página 34 3. CONFIGURAR LA FUERZA DE LA SEÑAL Si desea cambiar la configuración del AP. Siga la siguiente configuración. 1. Asigne una dirección IP estática a la PC en el mismo rango que el AP Nota: La máscara de subred debe ser “255.255.0.0”...
  • Página 35 Configuración de distancia: el valor predeterminado es dos kilómetros, debe configurarse de acuer- do con sus necesidades. (Se debe establecer el mismo valor de distancia en el transmisor y el recep- tor. De lo contrario, se producirá una conexión de red de baja latencia y bajo ancho de banda). 4.
  • Página 36 de acuerdo con las instrucciones para un dispositivo DIP de 8 dígitos. (Centrándose en los botones 1 a 8 solamente). P8: Después de conectar el AP al NVR, puedo ver la dirección IP de la cámara, pero no la imagen. R8: Intente cambiar el puerto LAN del AP.
  • Página 37 5. 128 PARES DE CÓDIGOS, SEGMENTO Y FRECUENCIA PUEDE REFERIRSE AL SIGUIENTE GRÁFICO Group 2-8 Dial IP Segment 5.8GHz IP Segment 2.4GHz n° 1 172.18.0.X 5160 172.17.0.X 2412 n° 2 172.18.1.X 5180 172.17.1.X 2417 n° 3 172.18.2.X 5200 172.17.2.X 2422 n°...
  • Página 38 n° 20 172.18.19.X 5825 172.17.19.X 2452 n° 21 172.18.20.X 5160 172.17.20.X 2457 n° 22 172.18.21.X 5180 172.17.21.X 2462 n° 23 172.18.22.X 5200 172.17.22.X 2412 n° 24 172.18.23.X 5220 172.17.23.X 2417 n° 25 172.18.24.X 5240 172.17.24.X 2422 n° 26 172.18.25.X 5745 172.17.25.X 2427 n°...
  • Página 39 n° 41 172.18.40.X 5160 172.17.40.X 2447 n° 42 172.18.41.X 5180 172.17.41.X 2452 n° 43 172.18.42.X 5200 172.17.42.X 2457 n° 44 172.18.43.X 5220 172.17.43.X 2462 n° 45 172.18.44.X 5240 172.17.44.X 2412 n° 46 172.18.45.X 5745 172.17.45.X 2417 n° 47 172.18.46.X 5765 172.17.46.X 2422 n°...
  • Página 40 n° 62 172.18.61.X 5180 172.17.61.X 2442 n° 63 172.18.62.X 5200 172.17.62.X 2447 n° 64 172.18.63.X 5220 172.17.63.X 2452 n° 65 172.18.64.X 5240 172.17.64.X 2457 n° 66 172.18.65.X 5745 172.17.65.X 2462 n° 67 172.18.66.X 5765 172.17.66.X 2412 n° 68 172.18.67.X 5785 172.17.67.X 2417 n°...
  • Página 41 n° 83 172.18.82.X 5200 172.17.82.X 2437 n° 84 172.18.83.X 5220 172.17.83.X 2442 n° 85 172.18.84.X 5240 172.17.84.X 2447 n° 86 172.18.85.X 5745 172.17.85.X 2452 n° 87 172.18.86.X 5765 172.17.86.X 2457 n° 88 172.18.87.X 5785 172.17.87.X 2462 n° 89 172.18.88.X 5805 172.17.88.X 2412 n°...
  • Página 42 n° 104 172.18.103.X 5220 172.17.103.X 2432 n° 105 172.18.104.X 5240 172.17.104.X 2437 n° 106 172.18.105.X 5745 172.17.105.X 2442 n° 107 172.18.106.X 5765 172.17.106.X 2447 n° 108 172.18.107.X 5785 172.17.107.X 2452 n° 109 172.18.108.X 5805 172.17.108.X 2457 n° 110 172.18.109.X 5825 172.17.109.X 2462 n°...
  • Página 43 n° 125 172.18.124.X 5240 172.17.124.X 2427 n° 126 172.18.125.X 5745 172.17.125.X 2432 n° 127 172.18.126.X 5765 172.17.126.X 2437 n° 128 172.18.127.X 5785 172.17.127.X 2442...
  • Página 44 For any information and product updates > visit our website www.machpower.it Mach Power® is a registered trademark All rights reserved REV01-060521...

Este manual también es adecuado para: