ELECTRICAL
DOUBLE INSULATION
Double insulation is a concept in safety in electric power tools,
which eliminates the need for the usual three-wire grounded
power cord. All exposed metal parts are isolated from the
internal metal motor components with protecting insulation.
Double insulated tools do not need to be grounded.
WARNING:
The double insulated system is intended to
protect the user from shock resulting from a
break in the tool's internal wiring. Observe all
normal safety precautions to avoid electrical
shock.
NOTE: Servicing of a product with double insulation requires
extreme care and knowledge of the system and should
be performed only by a qualified service technician. For
service, we suggest you return the tool to your nearest
authorized service center for repair. Always use original
factory replacement parts when servicing.
ELECTRICAL CONNECTION
This tool has a precision-built electric motor. It should be
connected to a power supply that is 120 V, AC only (normal
household current), 60 Hz. Do not operate this tool on
direct current (DC). A substantial voltage drop will cause a
loss of power and the motor will overheat. If the tool does
not operate when plugged into an outlet, double check the
power supply.
POLARIZED PLUGS
See Figure 1.
To reduce the risk of electric shock, this tool has a polarized
plug (one blade is wider than the other). This plug will fit in
a polarized outlet only one way. If the plug does not fit fully
in the outlet, reverse the plug. If it still does not fit, contact
a qualified electrician to install the proper outlet. Do not
change the plug in any way.
EXTENSION CORDS
When using a power tool at a considerable distance from
a power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter's Laboratories
(UL) should be used.
When working outdoors with a product, use an extension
cord that is designed for outside use. This type of cord is
designated with "WA" or "W" on the cord's jacket.
Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
**Ampere rating (on tool faceplate)
0-2.0
Cord Length
25'
16
50'
16
100'
16
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working
area. Position the cord so that it will not get
caught on lumber, tools or other obstructions
while you are working with a power tool. Failure
to do so can result in serious personal injury.
WARNING:
Check extension cords before each use. If
damaged replace immediately. Never use
product with a damaged cord since touching
the damaged area could cause electrical shock
resulting in serious injury.
8 − English
2.1-3.4
3.5-5.0
5.1-7.0 7.1-12.0
Wire Size (A.W.G.)
16
16
16
16
16
14
16
14
12
POLARIZED
PLUG
12.1-16.0
14
14
14
12
10
Fig. 1