WATER INSTALLATION:
To achieve a good heater installation, verify the type of water feed system you have at your home, there
are two di erent types:
Open System (with a cistern): to supply water to the heater, an air tube must be installed at the cold water
inlet:
The air tube installation must not be omitted for the cold-water inlet, and we recommend installing one
for the hot water outlet also.
The air tube discharge must be slightly higher than the upper level of the cistern by at least 20 cm (see
Fig. 3).
Long segments of piping and/or accessories such as: elbows, T connections, distributing valves, etc.,
should be avoided (the recommended distance between the heater and the point of use should not
exceed 10 m).
To have the correct hot water pressure the cistern must be at least 2 m above the shower
level.
IMPORTANT: in the Open System, DO NOT INSTALL the included relief valve, because it
could cause a loss of line pressure.
Closed or Pressurized System (direct from the water system): regarding the heater's water supply, we
recommend installing a relief valve (INCLUDED) at the hot water outlet, calibrated at (0.68 MPa)
) (100 psi) (see Fig. 3).
(7 kg/cm
2
IMPORTANT: when there is excessive pressure, water exits through the relief valve. This is a
normal mechanism and does not mean the heater has malfunctioned. Avoid undue water spills by
installing a drainage tube at the relief valve exit towards the drains.
Maximum operating pressure of 7,13 kg /cm (0,7 MPa)
We recommend checking the relief valve (included) at least once a year to make sure it is in good working
condition.