Descargar Imprimir esta página

Calorex LEVARE 15 Instructivo De Instalación, Operación Y Mantenimiento página 23

Calentador de depósito eléctrico

Publicidad

Idiomas disponibles

Idiomas disponibles

23 / EN
Follow the numbered steps below for a correct installation:
Check that the voltage is appropriate for this appliance; you can verify the voltage on the product data
1.
label (placed on one side of the heater).
Install the water heater as close as possible to the electric current (charging center), with the voltage
2.
that will be used, which must be accessible and must include a switch break or QO breaker.
As a safety measure, it is obligatory to install a 20 Amp thermo-magnetic circuit breaker independently
3.
of the main line, for automatic deactivation in the case of an electrical fault or imbalance.
4.
Extend or lead the independent cables from the power supply through a conduit tube or polyduct to
the heater.
5.
Use no. 12 caliber THW cable for the connections, which must be made with a rat-tail splice.
We recommend using the colors used in the water heater wiring.
Ensure and verify that the green physical ground wire is correctly connected to the terminal at the
6.
charging center.
7.
Insulate or tape the splices with non-inflammable plastic insulating tape.
8.
Fill the heater with water to allow the air to exit. Open a hot water service until water comes out the
service line.
9.
Once the above has been completed, you can power the heater to start its operation. Never omit the
electric circuit's ground connection (see Fig. 5). We recommend connecting the green ground wire to
a copper rod (Copperweld).
Grounding is obligatory for this device, and the cable (which should be a yellow-green color and
10.
longer than the phase cables) must be attached to the ground connection.
Grounding Diagram
FIG. 5
Wire
Copper rod
Varilla de cobre
(Copperwed),
(Copperwed) de
1
/
" diameter x 1 m long
2
diámetro de 1/2" x 1 m
de longitud

Publicidad

loading

Este manual también es adecuado para:

Levare 30