English
20 Warranty
Our equipment is under warranty for at least 12 months with re‑
gard to material or production faults in accordance with national
legislation. In the EU countries, the warranty period for exclusively
private use is 24 months (an invoice or delivery note is required as
proof of purchase).
Damage resulting from, in particular, normal wear and tear,
overloading, improper handling, or caused by the user or other
damage caused by not following the operating instructions, or
any fault acknowledged at the time of purchase, is not covered by
the warranty.
Complaints will only be acknowledged if the equipment has
not been dismantled before being sent back to the suppliers or
to an authorised NAREX customer support workshop. Store the
operating instructions, safety notes, spare parts list and proof of
purchase in a safe place. In addition, the manufacturer's current
warranty conditions apply.
Note
Due to continuous research and development work, we reserve
the right to make changes to the technical content of this docu‑
mentation.
21 Certificate of Conformity
CPR 350:
We declare that the device meets requirements of the following
standards and directives.
Safety:
EN 62841‑1:2015
EN 62841‑4‑1:2020
Directive 2006/42/EC
Directive 2000/14/EC
Electromagnetic compatibility:
EN 55014‑1: 2021
EN 55014‑2: 2021
Directive 2014/30/EU
RoHS:
Directive 2011/65/EU
Method of assessment of conformity:
Article 12 of Directive 2006/42/EC
Certificado de examen de tipo:
M6A 094333 0021
Certificate issued by notified body:
TÜV SUD Product service GmbH
Ridlerstrasse 65
80339 Munich
Germany
Place of storage of the technical documentation:
Narex s.r.o., Chelčického 1932, 470 01 Česká Lípa, Czech Republic
32
21.1 Information about noise level and
vibrations
The values have been measured in conformity with EN 62841.
Acoustic pressure level L
= 78.6 dB (A).
pA
Acoustic power level L
= 86.6 dB (A).
wA
In accuracy of measurements K = 3.0 dB (A).
Guaranteed level of acoustic pressure is 90 dB (A).
ATTENTION! Noise is generated during work!
Use ear protection!
The weighted value of vibrations affecting hands and arms
a
= 4.382 m.s
.
‑2
h
In accuracy of measurements K = 1,5 m.s
The emission values specified (vibration, noise) were measured in
accordance with the test conditions stipulated in EN 62841 and
are intended for machine comparisons. They are also used for
making preliminary estimates regarding vibration and noise loads
during operation.
The emission values specified refer to the main applications for
which the power tool is used. If the electric power tool is used for
other applications, with other tools or is not maintained sufficient‑
ly prior to operation, however, the vibration and noise load may
be higher when the tool is used.
Take into account any machine idling times and downtimes to
estimate these values more accurately for a specified time period.
This may significantly reduce the load during the machine oper‑
ating period.
2023
Narex s.r.o.
Chelčického 1932
470 01 Česká Lípa
‑2
.
Jaroslav Hybner
CEO of the company
December 1, 2023