Safety edge test
0 = disabled
1 = active
Length of the partial opening travel (PAR) expressed as a
percentage of the total travel.
NOTE: only the leaf relating to the M1 motor opens
Automatic re-closing time from partial opening PAR (0 = off)
Determines the behaviour of the FLASH output
0 = output always active (not flashing) during the opening and
closing manoeuvre
1 = output flashing during the opening and closing
manoeuvre
Determines the pre-flashing modes of the FLASH output
(deactivated if PRE TIME = 0)
0 = pre-flashing before each opening and closing manoeuvre
1 = pre-flashing before each closing manoeuvre
2 = pre-flashing before each opening manoeuvre
Determines the duration of the pre-flashing (0 = off)
Courtesy light configuration
0 = on during the manoeuvre and, at the end of the
manoeuvre, for the
1= on if the gate is not closed for the
with the gate closed.
2 = lit for a
time after each command
(OPEN, CLOSE, PAR, SBS)
Courtesy light switching on time.
NOTE: the courtesy light can also be turned on and off by radio
remote control; if turned on by radio emote control, it can only
be turned off by radio remote control.
Enables the "man present" functionality on the SBS, PAR,
OPEN and CLOSE inputs
!
WARNING
enabling the function, the operation of the
radio remote controls is inhibited
Determines the operation of the IND/ELEC output
0 = off
1 = gate open indicator active if the gate is not closed
2 = proportional gate open indicator
- Slow flashing during opening
- Fast flashing during closing
- Two flashes + pause if stopped and not closed
3 = electric lock
4 = magnetic lock, output active if the gate is closed.
!
WARNING
interface the magnetic lock with a relay with
24VDC coil and set ELECT TIME ≠ 0.
Specifies the number of manoeuvres before reporting a
maintenance request.
NOTE: the signalling occurs using the FLASH output; if closed
it flashes continuously
Enables maintenance request reporting
0 = disabled
1 = active
Electric lock activation time or magnetic lock deactivation time.
Water hammer on opening (0 = off).
When closed, it pushes to close before opening; it is used to
facilitate the release of the electric lock
Water hammer on closing (0 = off).
At the end of the closing manoeuvre, the motor is kept active
for the set time; it is used to facilitate the coupling of the
electric lock.
Release on opening and closing limit switches.
0 = no release
10 = maximum release
In the presence of light gates, it reduces the bending of the
leaf.
0
0
1
50
0
100
0
0
900
1
0
1
0
0
2
0
0
20
0
0
2
0
0
900
0
0
1
0
0
4
X1000
10
0
200
cycles
0
0
1
2
1
10
0
0
100
100 ms
0
0
100
100 ms
0
0
10
%
s
s
s
s