3.2
Display and control elements
Switch
Function
position
Vacuum cleaner is switched
0
off
I
Vacuum cleaner is running
Standby mode for ON/OFF
A
automatic mode
RA
Standby mode for ON/OFF
automatic mode
Automatic filter cleaning
function
Fill level indicator
Setting the suction hose
diameter
3.3
Commissioning
Before every use make sure that the following conditions are met:
- Vacuum cleaner, mains cable, suction hose and accessories are not damaged.
- All filters have been inserted and are not damaged.
Switching on and off:
The plug socket on the vacuum cleaner remains always under voltage, regardless of the main
switch position.
Danger of injury by automatically starting power tool! Switch off power tool or pneumatic
tool before connecting to the vacuum cleaner!
Note: With switch in position >0<, the plug socket on the vacuum cleaner can be used as an ex-
tension cable. Power consumption: vacuum cleaner + connected power tool (max. 2000 W)
max. 16 A.
Switching on the vacuum cleaner:
Insert plug into plug socket.
Set switch to position >I<. Vacuum cleaner starts immediately.
or
Set switch to position >A< or >RA<. Vacuum cleaner is in standby mode for power tools.
Setting the suction hose diameter:
Set suction hose diameter at the switch.
Selector switch for minimum air volume flow signal (horn and light) on vacuum cleaners
with dust classes „M". In the modes >RA< and >I< the following setting is made, depend-
ing on the diameter of the hose:
Selector switch for
suction hose inner diameter
∅ 35 mm
∅ 27 mm
∅ 21 mm
The speed can be adjusted individually after setting the hose diameter.
18
Description
Plug socket under voltage
Plug socket under voltage, Automatic filter cleaning
function off
Plug socket under voltage, The vacuum cleaner is
switched on and off via the connected electri-
cal/compressed air tool at the plug socket
Standby mode like >A< plus automatic filter cleaning
Filter cleaning is performed automatically during the
next working break when the minimum volume flow
level is reached (switch setting RA)
When the container is full and/or there is a blockage
in the suction hose, the full indicator lights up. On the
M vacuum cleaners, an acoustic signal is also emit-
ted
On M vacuum cleaners for volume flow monitoring,
to trigger an audible warning signal if the air speed
falls below 20 m/s
Volume air
flow
70 l/s
41 l/s
25 l/s
ENGLISH
(A)