Descargar Imprimir esta página

HomeMatic IP HmIP-SMO230 Manual De Instalacion Y Uso página 30

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Troubleshooting
10.3 Error codes and flashing sequences
Flashing code
Fast orange flashing
1x long green flash
1x long red flash
Short orange flashes
(every 10 seconds)
Flashing green
(for one second each)
6x long red flashes
1x orange and 1x green light
(after inserting batteries)
Alternating long and
short orange flashing
System LED (indicates the switching status of the internal actuator)
Continuous green light
LED off
Main lens LED
Brief red flashing (approx. 1 s) Visualisation of a detected movement in zone 1
Brief green flashing (approx.
1 s)
Brief blue flashing (approx. 1 s) Visualisation of a detected movement in zone 3
Brief yellow flashing (approx.
1 s)
Brief magenta flashing
(approx. 1 s)
Brief turquoise flashing(ap-
prox. 1 s)
Brief white flashing (approx.
1 s)
Meaning
Configuration data is
transmitted
Operation confirmed
(pairing or restoring facto-
ry settings)
Operation failed (pairing
or restoring factory set-
tings) or duty cycle limit is
reached
Pairing mode active
(for 3 minutes)
Function test
Device defective
Test display
Software update (OTAU)
Actuator is switched on
Actuator is switched off
Visualisation of a detected movement in zone 2
Visualisation of a detected movement in zone 1 + 2
Visualisation of a detected movement in zone 1 + 3
Visualisation of a detected movement in zone 2 + 3
Visualisation of a detected movement in zone 1, 2 +
3
Solution
Wait until the transmission
is completed.
You can continue opera-
tion.
Please try again (or see sec.
see „10.2 Duty cycle" on
page
29).
Enter the last four digits of
the device serial number
to confirm
(see „9 Function
test" on page
29).
Please wait until the func-
tion test has finished after
10 minutes
(see „9 Function
test" on page
29).
Please see your app for
error message or contact
your retailer.
You can continue once the
test display has stopped.
Wait until the update is
completed.
30

Publicidad

loading

Este manual también es adecuado para:

Hmip-smo230-a