Vacuum System Motor Filter Cleaning; Solution Filter Cleaning - Clarke CR 28 BOOST Libro De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

VACUUM SYSTEM MOTOR FILTER CLEANING

1.
Drive the machine to the appointed disposal area and drain the water from the recovery tank (60) with the hose (10).
2.
Drain the solution from the tank (61) with the tap (24).
3.
Drive the machine on a level ground.
4.
Turn the ignition key (42) to "0".
5.
Disconnect the vacuum hose (11) from the squeegee (12).
6.
Fully lift the tank assembly (71) with care.
7.
Remove the vacuum system motor fi lter (77) and clean it with water and compressed air.
8.
Install the fi lter.
9.
Fully lower the tank assembly (71) with care.

SOLUTION FILTER CLEANING

1.
Drive the machine on a level fl oor.
2.
Turn the ignition key (42) to "0".
3.
Close the solution valve (E, Fig. 6) under the machine, behind the right rear wheel. The valve (E) is closed when it is on the
position (F) and it is open when it is on the position (G).
4.
Remove the transparent cover (A), then remove the fi lter strainer (B) under the machine in front of the right rear wheel. Clean
and reassemble the components on the support (C).
NOTE
The fi lter strainer (B) must be correctly positioned on the housing (D) of the support (C).
5.
Open the valve (E).
Figure 6
Operator's Manual - CR 28 BOOST®
ENGLISH
S311214A
21