6.2
Storage conditions
This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For
longer periods of storage, it is recommended to contact your nearest agent or to start up the unit for a few hours every year,
ensuring that the storage procedure is respected afterwards.
Drain the fuel and change the engine oil:
1.
Start the unit and allow it to operate until it runs out of fuel.
2.
Set the switch to OFF (A7).
3.
Clean the screen filter (A4) and the sediment bowl (A12-C6).
4.
Close the fuel tap (A5).
5.
Top up the oil.
Grease the cylinder and valves:
6.
Remove the spark plug (A14-F2) (see the section "Replace the spark plug") then, via its aperture, pour in approximately
one teaspoon of new engine oil.
7.
Refit a new spark plug in its place.
8.
Pull the starter-recoil reel handle (A9) several times to distribute the oil inside the cylinder.
Storing the unit:
9.
Clean the unit.
10. Cover it with a protective cover and store it in its normal position, in a clean, dry and well ventilated area.
The unit...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
7.1
Generator Smart Care (Option)
If the unit has been equipped with the "GS101-Generator Smart Care" option (A16),
it is necessary to change the batteries in the Bluetooth GSC101 box when the
warning is displayed in the Generator Smart Care application (approximately every
two years).
1.
Use a small crosshead screwdriver to open the cover of the box,
2.
Remove the used batteries and take them to a waste collection point so
that they can be recycled,
3.
Fit two new AAA batteries, observing the polarity (+/-),
4.
Close the unit cover and carefully tighten the screws.
1122_EN
Check that:
The checks before starting have been
performed.
YES
The start-up procedure has been
followed correctly.
YES
The equipment to be used has not
been connected prior to starting.
YES
The spark plug is in good condition and
correctly connected.
YES
The oil level is correct.
YES
The fuel level is correct.
YES
The air filter is in good condition.
YES
Maintenance has been correctly
performed on the unit components.
YES
Have the unit checked by one of our
agents*.
The circuit breaker(s) has/have been
tripped.
YES
The connected equipment and their
power cords are not faulty.
YES
Have the unit checked by one of our
agents*.
22/240
Section 7. Repairing minor faults
Solutions to be applied:
Perform the necessary checks.
NO
Re-read the start-up procedure and repeat
the start-up attempt.
NO
Disconnect the equipment then try to start
NO
the unit again.
Replace the spark plug (330830012).
NO
Top up with oil.
NO
Fill up with fuel.
NO
Clean the air filter.
NO
Perform maintenance on the unit as per
the recommendations.
NO
Check the capacity of the unit and press
the circuit breakers.
NO
Try with another item of equipment and
another power cord.
NO
*France: 0.806.800.107 (call charge).
2022-08-17