TEMPERATURE & SAFETY PROTECTION:
INTERNAL OVERHEAT PROTECTION: The charger has a built-in overheat and an overload protection. This protects the charger
from being damaged if overheated or overloaded and will automatically decrease the charging current. Once the unit's internal
temperature decreases to a safe level, the charger will resume normal charging.
SAFETY TIMER PROTECTION: The charger has safety timers for every stage. If the battery voltage doesn't reach a certain
voltage within a certain amount of time, the unit will stop charging as it's highly likely that you're attempting to charge a severely
discharged or heavily sulphated battery. If any of the stages time out, the charger will immediately stop charging in order to protect the
battery. This will be indicated with the ERROR LED flashing slowly.
REVERSE POLARITY: The charger has a reverse polarity protection. If the charger output leads are connected with a reverse
polarity, the ERROR LED will light on and the charger will be disabled. Simply unplug the charger from AC power and then connect
the output leads to the correct polarity.
SHORT CIRCUIT PROTECTION: The charger will automatically turn off if the output leads are short circuited and the ERROR
LED will light on. This prevents the charger from being damaged if the positive and negative crocodile clips or the optional ring
terminals accidently touch each other while the charger is turned on.
ECO MODE: This battery charger has a built in ultra-low power consumption circuit. If AC power is connected and the battery is
disconnected, after 10 seconds the charger will automatically go into an ECO mode. During this mode the power drawn is less than
0.36W which totals 0.01kWh per day power consumption. If AC power is connected and the battery is connected, once the battery is
fully charged and during the long term maintenance stage, the total power consumption is around 0.03kWh per day.
Both the selected charge rate and battery type LED's will flash GREEN to indicate ECO mode.
BATTERY TYPES & CAPACITY:
Suits 12V conventional lead acid batteries (VRLA) AGM, Calcium, Gel & Wet. The Ah (Ampere Hours) capacities shown below are
to be used as a general guide only. Some batteries may be able to handle a higher charge current. Refer to the battery manufacturer's
specifications and recommendations for your charging requirements.
Charge Rate:
1A
Charging
3 - 20Ah
Maintaining
< 100Ah
ELECTRICAL PARTS & ACCESSORIES:
AC Power Cord:
DC Output Lead:
Charging Leads:
TECHNICAL SPECIFICATIONS:
Output
Input Voltage
Input Frequency
Charge Voltage
Equalizing Voltage
Float Voltage
Start Voltage
Operating Temperature
Storage Temperature
Operating Humidity
Size (L x W x H)
Weight
Approvals
CHARGING INSTRUCTIONS:
STEP 1 - Pre charge check & electrolyte level check
Check the Battery Electrolyte levels (Not required on sealed & maintenance free batteries). If necessary, remove the vent caps and add
distilled water so the levels are halfway between the upper and lower fill lines.
Check the battery voltage, type and Ah capacity to ensure the charger is compatible and to determine which Battery Type and Charge
Rate settings you will use.
Ensure the battery is in a well-ventilated area and the charger should be as far away from the battery as the cables permit.
4A
12 - 80Ah
< 120Ah
1.8m with 2 Pins Plug
1.2m with quick connect
Quick connect 60cm with Crocodile Clips + Quick connect 60cm
with fused ring terminals
6A @ 12V
100-240Vac / 1.4A(95W)
50/60Hz
Gel - 14.1V
AGM & WET - 14.4V
Calcium - 14.7V
Gel - 14.3V
AGM & WET - 14.6V
Calcium - 15.5V
13.6V
3V
-15 to 50° C
-25 to 85°C
90% RH Max.
182mm x 88mm x 48mm
0.75kg
CE
6A
18 - 120Ah
< 180Ah